If the server has fewer than the maximum number of
WARNING! Ensure that the system is powered off and all power sources have been disconnected from the server prior to performing this procedure.
Voltages are present at various locations within the server whenever an ac power source is connected. This voltage is present even when the main power switch is in the off position.
Failure to observe this warning can result in personal injury or damage to equipment.
CAUTION: Intel Montvale processors cannot be intermixed with similar Montecito processors. Processor speed and cache size must be identical for all processors in a system. Whether upgrading, replacing or adding an additional processor, to ensure compatibility use processors with identical part numbers.
Failure to observe this caution results in performance degradation or system failure.
CAUTION: Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD safety precautions can result in damage to the server.
Processor Load OrderThe server can have up to two
Table
Table
Slot | |
|
|
1 | Module 0 |
|
|
2 | Module 1 |
|
|
To install and remove processors, use the processor install tool fastened to the processor board.
Removing aTo remove a
1.Power off the server and disconnect the power cables. See “Powering Off the Server” (page 95).
2.If rack installed, slide the server out from the rack until it stops. See “Extending the Server from the Rack” (page 180).
3.Remove the memory carrier assembly cover. See “Removing the Memory Carrier Assembly Cover” (page 183).
NOTE: You do not need to fully remove the top cover to service this component; however, the top cover release lever must be open. You must remove the memory carrier because it attaches directly to the processor board.
4.Remove the memory carrier assembly. See “Removing the Memory Carrier Assembly” (page 204).
5.Remove the processor board assembly. See “Removing the Processor Board Assembly” (page 217).
Removing and Replacing a