Power Meter Operation

Selecting a Digital or Analog Display

To select the format of the display in the currently selected window:

1. Press SetupMeas

,

Display Format .

2.Press Meter Dgtl Anlg to highlight the type of format you require. Pressing this key toggles between a digital and analog display.

To select the range of the analog display in the currently selected window:

1. Press SetupMeas

,

Display Format ,

Anlg Mtr Scaling .

2.The current setting of the maximum and minimum values displayed on the analog meter are displayed under the Max and Min softkeys respectively.

3.To change either of these settings press the appropriate softkey. The power meter displays the current value in a pop up window. Modify this value (see below) until the desired value is displayed.

Use or to modify the digit on which the cursor is currently positioned.

Use or to move to other digits.

4.The choices available depend on the unit of measurement selected and the current measurement mode. If the measurement unit selected is logarithmic, then the choice will be dB or dBm. If the measurement unit selected is linear, then choose the appropriate softkeys from the following menus:

More

%

Cancel

%

Increment

Multiplier

Decrement

Multiplier

Cancel

More

mW

μW

nW

Cancel

W

Increment

Multiplier

Decrement

Multiplier

Cancel

Pressing Increment Multiplier or

Decrement Multiplier increases or decreases the multiplier