Manuals
/
HP
/
Power Tools
/
Saw
HP
Saw E4419B
manual
Contents-8 HP E4419B User’s Guide
Models:
Saw E4419B
1
20
204
204
Download
204 pages
1024 b
17
18
19
20
21
22
23
24
<
>
General Characteristics
Install
Error codes
TTL Input Timing Diagram
Measuring Pulsed Signals
Default
Window Symbols
Pass/Fail Limit Indicators
Warranty
Dimension
Page 20
Image 20
Contents-8
HP E4419B User’s Guide
Page 19
Page 21
Page 20
Image 20
Page 19
Page 21
Contents
User’s Guide
HP Part no. E4419-90006 December
Page
Certification
Warranty
Legal Information
Limitation of Warranty
Exclusive Remedies
Personal Safety Considerations
Equipment Operation
General Safety Considerations
Markings
Installation Instructions
IEC 1010-1 Compliance
Statement of Compliance
User Environment
Regulatory Information
Sound Emission
Australian EMC Regulations
Herstellerbescheinigung
Declaration of Conformity
List of Related Publications
HP E4418B/E4419B Programming Guide is shipped as standard
Available Accessories
HP E4419B Options
About this Guide
Table of Contents
Page
HP-IB
Page
List of Figures
Contents-6 HP E4419B User’s Guide
List of Tables
Contents-8 HP E4419B User’s Guide
Getting Started
Introduction
Turning On the Power Meter
Connect the power cord and turn on the power meter
Connect the power sensors
Set the display contrast if required
Front Panel at a Glance
Hardkeys relating to the display layout
System/Inputs hardkey with softkey menu
Dedicated Window hardkeys with softkey menus
Dedicated Channel hardkeys with softkey menus
Channel Inputs
Power REF Output
Arrow hardkeys
Menu related hardkeys
Softkeys
Display Layout
Cal
Reference Upper Lower Number Display Line
CFxxx.x% Xxx.xyHza Nn,a
HP E4419B User’s Guide
Selecting Your Display Layout
Display Tutorial
HP E4419B User’s Guide
Confirmation Window
Window Symbols
Wait Symbol
N Entry Window
Numeric or Alphanumeric Entry Window
Rear Panel at a Glance
Rmt I/O
Ground Connector
Serial Label
Adjusting the Carrying Handle
Rack Mounting the Power Meter
Rack Mounting the Power Meter
Power Meter Operation
Power Meter Operation
Battery Operation Option
Battery Status
General Information
Running Time
Charging Times
Backlight
Battery Removal/Replacement
Battery Removal/Replacement
Zeroing and Calibrating the Power Meter
Zeroing the Power Meter
When to Zero?
Zero/Cal Lockout
Calibrating the Power Meter
Calibration Procedure Using HP E-Series Power Sensors
V8486A and W8486A sensors
Calibration Procedure using HP 8480 Series Power Sensors
Example
Models
Zeroing and Calibrating the Power Meter
Sensor Connection Requirements Model
Zeroing and Calibrating Using TTL Inputs
TTL Inputs Control Logic Operation
TTL Input Timing Diagram
Timing of zero/cal inputs for conditions 01
TTL Inputs Timing Diagram
Timing of zero/cal inputs for condition
Making Measurements with the HP E-Series Power Sensors
Procedure
Freq . Use
Making Measurements with the HP 8480 Series Power Sensors
Zero a Cal
Cal Fac . Use
Making Measurements using Sensor Calibration Tables
Selecting a Sensor Calibration Table
Making the Measurement
Sensor Tbls Screen
Editing Sensor Calibration Tables
Edit Cal Screen
Making Measurements using Sensor Calibration Tables
You can only edit the table name you cannot delete it
Default
R8486A
HP 8487A
Making Measurements using Frequency Dependent Offset Tables
Selecting a Frequency Dependent Offset Table
Offset Tbls Screen
Editing Frequency Dependent Offset Tables
Edit Screen
You delete the frequency the equivalent offset is also
Setting the Units of Measurement
Selecting Units of Measurement from the Softkeys
Making Relative Measurements
Setting the Resolution
Setting Display Offsets
Setting Offsets
Setting Channel Offsets
Effect of Offsets on a Channel Measurement
Setting Averaging
10 Averaged Readings
Step Detection
Measuring Pulsed Signals
11 Pulsed Signal
To set the duty cycle Press
Setting Measurement Limits
Setting Channel Limits
Setting Window Limits
12 Limits Checking Application
Range of Values for Window Limits Max Min Default Units
14 Remote I/O TTL Outputs
Checking for Limit Failures
15 Pass/Fail Limit Indicators
Channel Measurements
Making Difference Measurements
Making Ratio Measurements
Selecting a Digital or Analog Display
16 Digital Display
Display Format
Selecting a Digital or Analog Display
Setting the Range
Configuring the Remote Interface
HP-IB Address
RS232/422 Connector
RS232/RS422
Setting the RS232/422 Parameters
Remote Interface Overview
20 Interface Overview Examples
Programming Language Selection
21 Test Setup for Recording Swept Measurements
Recorder Outputs
Leveling a Source Output
Saving and Recalling Power Meter Configurations
22 Save/Recall Screen
How Measurements are Calculated
Window Functions
Presetting the Power Meter
Preset Conditions
Offset is set to 0.000 dB
Is set to Off HP E4419B User’s Guide
Power On Self Test
Self Test
Front Panel Selection of Self Tests
Instrument Self Test
Confidence Check
Remote Testing
Test Descriptions
Option 001 Battery
Calibrator
Keyboard Front Panel only
Display
Bitmap Display Front Panel only
Operator Maintenance
Replacing the Power Line Fuse
Contacting Hewlett-Packard
Before calling Hewlett-Packard
Check the Basics
Instrument serial numbers
OPT
Japan
Sales and Service Offices
Asia Pacific
Canada
South Africa 011 806
Switzerland 01 735
United Kingdom 01344 366
Latin America
Returning Your Power Meter for Service
Package the Power Meter For Shipment
HP E4419B User’s Guide
Menu Reference
Menu Reference
Front Panel Menu Maps
DBm/W Menu
Frequency/Cal Fac Menu
Meas Setup Menu
Rel/Offset Menu
Save/Recall Menu
System Inputs Menu 1
Auto
System Inputs Menu 2
000W
System Inputs Menu 3
Scpi
System Inputs Menu 4
Zero/Cal Menu
Front Panel Menu Reference
Freq Cal Fac
Cal Fac
Front Panel Menu Reference Meas/Setup Menu
Meter Dgtl Anlg
TTL Output
Front Panel Menu Reference More, Preset/Local, Prev Keys
Rel
Save
HP-IB
RS422
RTS/CTS
Echo
Freq Dep Offset
Linearity ATyp DTyp and B Linearity ATyp DTyp
Duty Cycle
Commonly used for troubleshooting. The default is Off
Press this softkey to return to the System/Inputs menu
Press this softkey to run a test on the internal cooling fan
Serial Interface
Set Contrast
Backlight On
Zero B
Off
Diagrammatical Hardkeys
Is implemented in the selected window
HP E4419B User’s Guide
Error Messages
Error Annunciator Position
Error List then Clear Errors
Error Messages
Undefined header
Invalid character in number
Exponent too large
Too many digits
Character data not allowed
Invalid string data
String data not allowed
Invalid block data
Parameter errorFrequency list must be in ascending order
Settings conflict
Settings conflictDTR/DSR not available on RS422
Trigger deadlock
Data questionableCAL Error ChA
Data corrupt or stalePlease zero and calibrate Channel a
Data corrupt or stalePlease zero and calibrate Channel B
Data corrupt or stalePlease zero Channel a
Data questionableCAL Error ChB
Data questionableLower window log error
Data questionableUpper window log error
Data questionableZERO Error ChA
System errorCh B Dty Cyc may impair accuracy with ECP
System errorDetector Eeprom Read Failed critical data not
System errorDetector Eeprom Read Completed OK but
System errorDetector Eeprom Read Failed unknown
Self-test FailedMeasurement Channel a Fault
Self-test FailedMeasurement Channel B Fault
Self-test FailedOption 001 Battery requires replacement
Self-test FailedRAM Battery Fault
Self-test FailedSerial Interface Fault
Parity error in program
Framing error in program
Queue overflow
Specifications
Specifications
Power Meter Specifications
Meter
Instrumentation
Zero Set Specifications Power Sensor
Accuracy
Accuracy
Power Reference
Power Output
Power Meter Supplemental Characteristics
Connector
Measurement Speed
Frequency
Zero Drift of Sensors
Measurement Noise
Noise Multiplier Number
Averages
Power Sensor Specifications
Zero Drift Measurement Noise
For HP 8480 series power sensors
Normal Mode X2 Mode
Settling Time
Settling Time Number
For HP E-series power sensors
Normal Mode X2 Mode Maximum dBm
Power Sensor Specifications
Definitions Zero Set
Zero Drift
Measurement Noise
Battery Option 001 Operational Characteristics
General Characteristics
Rear Panel Connectors
Environmental Characteristics
General Conditions
Operating Environment
Storage Conditions
Dimensions
Weight
Safety
General
HP-IB Compatibility
Battery
Non-Volatile Memory
HP E4419B User’s Guide
Index
Index-2 HP E4419B User’s Guide
HP E4419B User’s Guide Index-3
Index-4 HP E4419B User’s Guide
HP E4419B User’s Guide Index-5
Index-6 HP E4419B User’s Guide
HP E4419B User’s Guide Index-7
Index-8 HP E4419B User’s Guide
Top
Page
Image
Contents