Manuals
/
HP
/
Power Tools
/
Saw
HP
Saw E4419B
manual
User’s Guide, HP Part no. E4419-90006 December
Models:
Saw E4419B
1
1
204
204
Download
204 pages
1024 b
1
2
3
4
5
6
7
8
General Characteristics
Install
Error messages
TTL Input Timing Diagram
Measuring Pulsed Signals
Default
Window Symbols
Pass/Fail Limit Indicators
Warranty
Dimension
Page 1
Image 1
User’s Guide
HP E4419B Power Meter
HP Part no.
E4419-90006
December, 1998
Page 1
Page 2
Page 1
Image 1
Page 1
Page 2
Contents
HP Part no. E4419-90006 December
User’s Guide
Page
Legal Information
Warranty
Certification
Exclusive Remedies
Limitation of Warranty
Equipment Operation
Personal Safety Considerations
Markings
General Safety Considerations
IEC 1010-1 Compliance
Installation Instructions
Statement of Compliance
User Environment
Sound Emission
Regulatory Information
Australian EMC Regulations
Herstellerbescheinigung
Declaration of Conformity
HP E4418B/E4419B Programming Guide is shipped as standard
List of Related Publications
HP E4419B Options
Available Accessories
About this Guide
Table of Contents
Page
HP-IB
Page
List of Figures
Contents-6 HP E4419B User’s Guide
List of Tables
Contents-8 HP E4419B User’s Guide
Getting Started
Introduction
Connect the power cord and turn on the power meter
Turning On the Power Meter
Connect the power sensors
Set the display contrast if required
Hardkeys relating to the display layout
Front Panel at a Glance
Dedicated Window hardkeys with softkey menus
System/Inputs hardkey with softkey menu
Dedicated Channel hardkeys with softkey menus
Channel Inputs
Arrow hardkeys
Power REF Output
Menu related hardkeys
Softkeys
Display Layout
Cal
CFxxx.x% Xxx.xyHza Nn,a
Reference Upper Lower Number Display Line
HP E4419B User’s Guide
Selecting Your Display Layout
Display Tutorial
HP E4419B User’s Guide
Wait Symbol
Window Symbols
Confirmation Window
Numeric or Alphanumeric Entry Window
N Entry Window
Rear Panel at a Glance
Serial Label
Ground Connector
Rmt I/O
Adjusting the Carrying Handle
Rack Mounting the Power Meter
Rack Mounting the Power Meter
Power Meter Operation
Power Meter Operation
Battery Status
Battery Operation Option
General Information
Running Time
Backlight
Charging Times
Battery Removal/Replacement
Battery Removal/Replacement
Zeroing the Power Meter
Zeroing and Calibrating the Power Meter
When to Zero?
Zero/Cal Lockout
Calibration Procedure Using HP E-Series Power Sensors
Calibrating the Power Meter
Example
Calibration Procedure using HP 8480 Series Power Sensors
V8486A and W8486A sensors
Models
Zeroing and Calibrating the Power Meter
Sensor Connection Requirements Model
TTL Inputs Control Logic Operation
Zeroing and Calibrating Using TTL Inputs
Timing of zero/cal inputs for conditions 01
TTL Input Timing Diagram
Timing of zero/cal inputs for condition
TTL Inputs Timing Diagram
Procedure
Making Measurements with the HP E-Series Power Sensors
Freq . Use
Making Measurements with the HP 8480 Series Power Sensors
Zero a Cal
Cal Fac . Use
Selecting a Sensor Calibration Table
Making Measurements using Sensor Calibration Tables
Sensor Tbls Screen
Making the Measurement
Editing Sensor Calibration Tables
Edit Cal Screen
Making Measurements using Sensor Calibration Tables
You can only edit the table name you cannot delete it
Default
R8486A
HP 8487A
Selecting a Frequency Dependent Offset Table
Making Measurements using Frequency Dependent Offset Tables
Offset Tbls Screen
Editing Frequency Dependent Offset Tables
Edit Screen
You delete the frequency the equivalent offset is also
Setting the Units of Measurement
Selecting Units of Measurement from the Softkeys
Making Relative Measurements
Setting the Resolution
Setting Channel Offsets
Setting Offsets
Setting Display Offsets
Effect of Offsets on a Channel Measurement
Setting Averaging
10 Averaged Readings
Step Detection
11 Pulsed Signal
Measuring Pulsed Signals
To set the duty cycle Press
Setting Channel Limits
Setting Measurement Limits
12 Limits Checking Application
Setting Window Limits
Range of Values for Window Limits Max Min Default Units
14 Remote I/O TTL Outputs
Checking for Limit Failures
15 Pass/Fail Limit Indicators
Channel Measurements
Making Difference Measurements
Making Ratio Measurements
16 Digital Display
Selecting a Digital or Analog Display
Display Format
Selecting a Digital or Analog Display
Setting the Range
HP-IB Address
Configuring the Remote Interface
RS232/RS422
RS232/422 Connector
Setting the RS232/422 Parameters
Remote Interface Overview
20 Interface Overview Examples
Programming Language Selection
Recorder Outputs
21 Test Setup for Recording Swept Measurements
Leveling a Source Output
Saving and Recalling Power Meter Configurations
22 Save/Recall Screen
Window Functions
How Measurements are Calculated
Preset Conditions
Presetting the Power Meter
Offset is set to 0.000 dB
Is set to Off HP E4419B User’s Guide
Self Test
Power On Self Test
Front Panel Selection of Self Tests
Confidence Check
Instrument Self Test
Remote Testing
Test Descriptions
Calibrator
Option 001 Battery
Keyboard Front Panel only
Display
Bitmap Display Front Panel only
Replacing the Power Line Fuse
Operator Maintenance
Before calling Hewlett-Packard
Contacting Hewlett-Packard
Instrument serial numbers
Check the Basics
OPT
Asia Pacific
Sales and Service Offices
Japan
Canada
Switzerland 01 735
South Africa 011 806
United Kingdom 01344 366
Latin America
Package the Power Meter For Shipment
Returning Your Power Meter for Service
HP E4419B User’s Guide
Menu Reference
Menu Reference
DBm/W Menu
Front Panel Menu Maps
Frequency/Cal Fac Menu
Meas Setup Menu
Save/Recall Menu
Rel/Offset Menu
Auto
System Inputs Menu 1
000W
System Inputs Menu 2
Scpi
System Inputs Menu 3
System Inputs Menu 4
Zero/Cal Menu
Front Panel Menu Reference
Freq Cal Fac
Cal Fac
Front Panel Menu Reference Meas/Setup Menu
Meter Dgtl Anlg
TTL Output
Front Panel Menu Reference More, Preset/Local, Prev Keys
Rel
Save
HP-IB
RS422
RTS/CTS
Echo
Freq Dep Offset
Linearity ATyp DTyp and B Linearity ATyp DTyp
Duty Cycle
Commonly used for troubleshooting. The default is Off
Press this softkey to return to the System/Inputs menu
Press this softkey to run a test on the internal cooling fan
Serial Interface
Set Contrast
Backlight On
Zero B
Off
Diagrammatical Hardkeys
Is implemented in the selected window
HP E4419B User’s Guide
Error Messages
Error Annunciator Position
Error List then Clear Errors
Error Messages
Invalid character in number
Undefined header
Exponent too large
Too many digits
Invalid string data
Character data not allowed
String data not allowed
Invalid block data
Settings conflict
Parameter errorFrequency list must be in ascending order
Settings conflictDTR/DSR not available on RS422
Trigger deadlock
Data corrupt or stalePlease zero and calibrate Channel a
Data questionableCAL Error ChA
Data corrupt or stalePlease zero and calibrate Channel B
Data corrupt or stalePlease zero Channel a
Data questionableLower window log error
Data questionableCAL Error ChB
Data questionableUpper window log error
Data questionableZERO Error ChA
System errorDetector Eeprom Read Failed critical data not
System errorCh B Dty Cyc may impair accuracy with ECP
System errorDetector Eeprom Read Completed OK but
System errorDetector Eeprom Read Failed unknown
Self-test FailedMeasurement Channel B Fault
Self-test FailedMeasurement Channel a Fault
Self-test FailedOption 001 Battery requires replacement
Self-test FailedRAM Battery Fault
Parity error in program
Self-test FailedSerial Interface Fault
Framing error in program
Queue overflow
Specifications
Specifications
Meter
Power Meter Specifications
Accuracy
Zero Set Specifications Power Sensor
Instrumentation
Power Output
Power Reference
Accuracy
Connector
Power Meter Supplemental Characteristics
Measurement Speed
Frequency
Measurement Noise
Zero Drift of Sensors
Noise Multiplier Number
Averages
Zero Drift Measurement Noise
Power Sensor Specifications
Normal Mode X2 Mode
For HP 8480 series power sensors
Settling Time
Settling Time Number
For HP E-series power sensors
Normal Mode X2 Mode Maximum dBm
Definitions Zero Set
Power Sensor Specifications
Zero Drift
Measurement Noise
Battery Option 001 Operational Characteristics
Rear Panel Connectors
General Characteristics
General Conditions
Environmental Characteristics
Operating Environment
Storage Conditions
Weight
Dimensions
Safety
General
Non-Volatile Memory
Battery
HP-IB Compatibility
HP E4419B User’s Guide
Index
Index-2 HP E4419B User’s Guide
HP E4419B User’s Guide Index-3
Index-4 HP E4419B User’s Guide
HP E4419B User’s Guide Index-5
Index-6 HP E4419B User’s Guide
HP E4419B User’s Guide Index-7
Index-8 HP E4419B User’s Guide
Top
Page
Image
Contents