2.For an xSeries 330 server: To set the remote alert attempts on the ASM processor, log in to the ASM processor. For more information, see “Remote Supervisor Adapter and ASM processor action descriptions” on page 7.
3.In the navigation pane, click Alerts and scroll down to the Monitored Alerts section.
4.Select the events you want the Remote Supervisor Adapter or ASM processor to monitor.
The remote alerts are categorized by the following levels of severity: v Critical
vWarning
vSystem
All alerts are stored in the event log and sent to all configured remote alert recipients.
Critical alerts
Critical alerts are generated for events that signal that the server is no longer functioning. If the Select all critical alerts check box is selected, an alert can be sent for any critical alert.
Table 3. Critical remote alerts
Alphanumeric | Event | Action |
pager code |
|
|
|
|
|
00 | Temperature irregularity | Generates an alert if any of the monitored temperatures are outside |
|
| critical threshold values. To view the threshold values, click the |
|
| temperature readings on the System Health page. If a critical |
|
| temperature condition is detected, the server shuts down and turns off, |
|
| regardless of the alert notification setting. |
|
|
|
01 | Voltage irregularity | Generates an alert if the voltages of any of the monitored power supplies |
|
| fall outside their specified operational ranges. To view the operational |
|
| ranges, click the voltage readings on the System Health page. If a critical |
|
| voltage condition is detected, the server shuts down and turns off, |
|
| regardless of the alert notification setting. |
|
|
|
02 | Tampering | Generates an alert if physical intrusion of the server box is detected. |
|
| Tamper monitoring is not available on some servers, in which case this |
|
| setting is ignored. |
|
|
|
03 | Multiple fan failure | Generates an alert if two or more of the cooling fans in the server fail. |
|
|
|
04 | Power failure | Generates an alert if any of the server power supplies fail. |
|
|
|
05 | Hard disk drive failure | Generates an alert if one or more of the hard disk drives in the server |
|
| fail. |
|
|
|
06 | VRM failure | Generates an alert if one or more voltage regulator modules (VRMs) fail. |
|
| This setting is ignored for servers without VRMs. |
|
|
|
| Reserved for future use. | |
|
|
|
Warning alerts
Warning alerts are generated for events that might progress to a critical/error level. If the Select all warning alerts check box is selected, an alert can be sent for any warning alert.