Table4. Warning remote alerts
Alphanumeric
pager code
Event Action
10 Redundantpower
supply failure
Generates an alert if a redundant power supply fails.
11 Singlefan failure Generates an alert if one fan fails.
12 Temperature irregularity Generatesan alert if any monitored temperatures are outside the
warning threshold values. Toaccess these temperature threshold values,
click the temperature readings on the System Health page. Unlike the
critical temperature event, this event will not initiate a server shutdown.
13 Voltage irregularity Generates an alert if any monitored voltages are outside the warning
threshold values. Toaccess these voltage range values, click the voltage
readings on the System Health page. Unlike the critical voltage event,
this event will not initiate an automatic server shutdown.
14 - 19 Reserved for future use.
System alerts
System alerts are generated for events that occur as a result of system
errors. If the Select all system alerts check box is selected, an alert
can be sent for any system alert.
Notes:
a. The Select all system alerts check box is not available on all
servers.
b. Hard disk drive Predictive Failure Analysis
®
(PFA) alerts are not
monitored.
Table5. System remote alerts
Alphanumeric
pager code
Event Action
20 POSTtimeout Generatesan alert if an enabled POST timeout value is exceeded. The
POST timeout value is configured in the Server Timeouts section on the
System page.
21 O/Stimeout Generates an alert if an enabled operating system timeout value is
exceeded. The operating system timeout value is configured in the
Server Timeouts section on the System page. The O/S timeout alert
must be checked to enable remote blue screen capture.
22 Test alert Generatesan alert if the Generate Test Alert button is clicked on the
Remote Alert Recipients page.
23 Poweroff Generatesan alert if the server is turned off.
24 Poweron Generatesan alert if the server is turned on.
25 Bootfailure Generates an alert if an error occurs that prevents the server from
starting.
26 Loadertimeout Generates an alert if an enabled server loader timeout value is
exceeded. The system loader timeout value is configured in the Server
Timeouts section on the System page.
27 PFA notification Generates an alert if a PFAnotification is generated by the server
hardware. This feature is available only on server that have PFA-enabled
hardware.
28 - 29 Reserved for future use.
5. Scroll to the bottom of the page and click Save.
28 Remote Supervisor Adapter: User’s Guide