Table 4. Warning remote alerts

Alphanumeric

Event

Action

pager code

 

 

 

 

 

10

Redundant power

Generates an alert if a redundant power supply fails.

 

supply failure

 

 

 

 

11

Single fan failure

Generates an alert if one fan fails.

 

 

 

12

Temperature irregularity

Generates an alert if any monitored temperatures are outside the

 

 

warning threshold values. To access these temperature threshold values,

 

 

click the temperature readings on the System Health page. Unlike the

 

 

critical temperature event, this event will not initiate a server shutdown.

 

 

 

13

Voltage irregularity

Generates an alert if any monitored voltages are outside the warning

 

 

threshold values. To access these voltage range values, click the voltage

 

 

readings on the System Health page. Unlike the critical voltage event,

 

 

this event will not initiate an automatic server shutdown.

 

 

 

14 - 19

 

Reserved for future use.

 

 

 

System alerts

System alerts are generated for events that occur as a result of system errors. If the Select all system alerts check box is selected, an alert can be sent for any system alert.

Notes:

a.The Select all system alerts check box is not available on all servers.

b.Hard disk drive Predictive Failure Analysis® (PFA) alerts are not monitored.

Table 5. System remote alerts

Alphanumeric

Event

Action

pager code

 

 

 

 

 

20

POST timeout

Generates an alert if an enabled POST timeout value is exceeded. The

 

 

POST timeout value is configured in the Server Timeouts section on the

 

 

System page.

 

 

 

21

O/S timeout

Generates an alert if an enabled operating system timeout value is

 

 

exceeded. The operating system timeout value is configured in the

 

 

Server Timeouts section on the System page. The O/S timeout alert

 

 

must be checked to enable remote blue screen capture.

 

 

 

22

Test alert

Generates an alert if the Generate Test Alert button is clicked on the

 

 

Remote Alert Recipients page.

 

 

 

23

Power off

Generates an alert if the server is turned off.

 

 

 

24

Power on

Generates an alert if the server is turned on.

 

 

 

25

Boot failure

Generates an alert if an error occurs that prevents the server from

 

 

starting.

 

 

 

26

Loader timeout

Generates an alert if an enabled server loader timeout value is

 

 

exceeded. The system loader timeout value is configured in the Server

 

 

Timeouts section on the System page.

 

 

 

27

PFA notification

Generates an alert if a PFA notification is generated by the server

 

 

hardware. This feature is available only on server that have PFA-enabled

 

 

hardware.

 

 

 

28 - 29

 

Reserved for future use.

 

 

 

5. Scroll to the bottom of the page and click Save.

28Remote Supervisor Adapter: User’s Guide

Page 34
Image 34
IBM Partner Pavilion Remote Supervisor Adapter manual System alerts