Table 4. Warning remote alerts
Alphanumeric | Event | Action |
pager code |
|
|
|
|
|
10 | Redundant power | Generates an alert if a redundant power supply fails. |
| supply failure |
|
|
|
|
11 | Single fan failure | Generates an alert if one fan fails. |
|
|
|
12 | Temperature irregularity | Generates an alert if any monitored temperatures are outside the |
|
| warning threshold values. To access these temperature threshold values, |
|
| click the temperature readings on the System Health page. Unlike the |
|
| critical temperature event, this event will not initiate a server shutdown. |
|
|
|
13 | Voltage irregularity | Generates an alert if any monitored voltages are outside the warning |
|
| threshold values. To access these voltage range values, click the voltage |
|
| readings on the System Health page. Unlike the critical voltage event, |
|
| this event will not initiate an automatic server shutdown. |
|
|
|
14 - 19 |
| Reserved for future use. |
|
|
|
System alerts
System alerts are generated for events that occur as a result of system errors. If the Select all system alerts check box is selected, an alert can be sent for any system alert.
Notes:
a.The Select all system alerts check box is not available on all servers.
b.Hard disk drive Predictive Failure Analysis® (PFA) alerts are not monitored.
Table 5. System remote alerts
Alphanumeric | Event | Action |
pager code |
|
|
|
|
|
20 | POST timeout | Generates an alert if an enabled POST timeout value is exceeded. The |
|
| POST timeout value is configured in the Server Timeouts section on the |
|
| System page. |
|
|
|
21 | O/S timeout | Generates an alert if an enabled operating system timeout value is |
|
| exceeded. The operating system timeout value is configured in the |
|
| Server Timeouts section on the System page. The O/S timeout alert |
|
| must be checked to enable remote blue screen capture. |
|
|
|
22 | Test alert | Generates an alert if the Generate Test Alert button is clicked on the |
|
| Remote Alert Recipients page. |
|
|
|
23 | Power off | Generates an alert if the server is turned off. |
|
|
|
24 | Power on | Generates an alert if the server is turned on. |
|
|
|
25 | Boot failure | Generates an alert if an error occurs that prevents the server from |
|
| starting. |
|
|
|
26 | Loader timeout | Generates an alert if an enabled server loader timeout value is |
|
| exceeded. The system loader timeout value is configured in the Server |
|
| Timeouts section on the System page. |
|
|
|
27 | PFA notification | Generates an alert if a PFA notification is generated by the server |
|
| hardware. This feature is available only on server that have |
|
| hardware. |
|
|
|
28 - 29 |
| Reserved for future use. |
|
|
|
5. Scroll to the bottom of the page and click Save.