6.Press F3 and select System Remote Alerts.
System alerts
System alerts are generated for events that occur as a result of system errors.
Table 20. System remote alerts
Alphanumeric | Event | Action |
pager code |
|
|
|
|
|
20 | POST timeout | Generates an alert if an enabled POST timeout value is exceeded. The |
|
| POST timeout value is configured in the Server Timeouts section in the |
|
| System window. |
|
|
|
21 | O/S timeout | Generates an alert if an enabled operating system timeout value is |
|
| exceeded. The operating system timeout value is configured in the |
|
| Server Timeouts section in the System window. This O/S timeout field |
|
| must be set to Enabled for remote blue screen capture. |
|
|
|
22 | Test alert | Generates an alert if Generate Test Alert is clicked on the Remote Alert |
|
| Recipients page. |
|
|
|
23 | Power off | Generates an alert if the server is turned off. |
|
|
|
24 | Power on | Generates an alert if the server is turned on. |
|
|
|
25 | Boot failure | Generates an alert if an error occurs that prevents the server from |
|
| starting. |
|
|
|
26 | Loader timeout | Generates an alert if an enabled system loader timeout value is |
|
| exceeded. The system loader timeout value is configured in the Server |
|
| Timeouts section in the System window. |
|
|
|
27 | PFA notification | Generates an alert if a PFA notification is generated by the server |
|
| hardware. This feature is available only on servers that have |
|
| |
|
|
|
28 - 29 |
| Reserved for future use. |
|
|
|
7. Press F3 and select Events For Local Notification.
8. Select the events that you want to store in the event log. The Remote
| Supervisor Adapter stores the notification only in the event log. | |
| Local events | |
|
| Local events are generated for events sent to IBM Director, if it is |
|
| installed, on the server where the ASM subsystem resides. These |
|
| events are not sent to remote alert recipients. |
Table 21. Local events |
|
|
|
|
|
Event |
| Action |
|
|
|
Temperature |
| Generates a local notification if any of the monitored temperatures exceeds their |
|
| thresholds. |
|
|
|
Voltage |
| Generates a local notification if any of the monitored voltages exceeds their threshold. |
|
|
|
Redundant power supply |
| Generates a local notification if the redundant power supply fails. |
|
|
|
Power off |
| Generates a local notification if the server is turned off. |
|
|
|
Remote login |
| Generates a local notification if a remote login occurs. |
|
|
|
System tamper |
| Generates a local notification if the server covers are removed. This feature is not |
|
| available on all servers. |
|
|
|
Event log 75% full |
| Generates a local notification if the event log reaches 75% of capacity. |
|
|
|
Event log full |
| Generates a local notification if the event log is full. When the event log is full, the |
|
| oldest events are deleted. |
|
|
|
Chapter 7. Configuring your Remote Supervisor Adapter using a