6.Press F3 and select System Remote Alerts.

System alerts

System alerts are generated for events that occur as a result of system errors.

Table 20. System remote alerts

Alphanumeric

Event

Action

pager code

 

 

 

 

 

20

POST timeout

Generates an alert if an enabled POST timeout value is exceeded. The

 

 

POST timeout value is configured in the Server Timeouts section in the

 

 

System window.

 

 

 

21

O/S timeout

Generates an alert if an enabled operating system timeout value is

 

 

exceeded. The operating system timeout value is configured in the

 

 

Server Timeouts section in the System window. This O/S timeout field

 

 

must be set to Enabled for remote blue screen capture.

 

 

 

22

Test alert

Generates an alert if Generate Test Alert is clicked on the Remote Alert

 

 

Recipients page.

 

 

 

23

Power off

Generates an alert if the server is turned off.

 

 

 

24

Power on

Generates an alert if the server is turned on.

 

 

 

25

Boot failure

Generates an alert if an error occurs that prevents the server from

 

 

starting.

 

 

 

26

Loader timeout

Generates an alert if an enabled system loader timeout value is

 

 

exceeded. The system loader timeout value is configured in the Server

 

 

Timeouts section in the System window.

 

 

 

27

PFA notification

Generates an alert if a PFA notification is generated by the server

 

 

hardware. This feature is available only on servers that have

 

 

PFA-enabled hardware.

 

 

 

28 - 29

 

Reserved for future use.

 

 

 

7. Press F3 and select Events For Local Notification.

8. Select the events that you want to store in the event log. The Remote

 

Supervisor Adapter stores the notification only in the event log.

 

Local events

 

 

Local events are generated for events sent to IBM Director, if it is

 

 

installed, on the server where the ASM subsystem resides. These

 

 

events are not sent to remote alert recipients.

Table 21. Local events

 

 

 

 

 

Event

 

Action

 

 

 

Temperature

 

Generates a local notification if any of the monitored temperatures exceeds their

 

 

thresholds.

 

 

 

Voltage

 

Generates a local notification if any of the monitored voltages exceeds their threshold.

 

 

 

Redundant power supply

 

Generates a local notification if the redundant power supply fails.

 

 

 

Power off

 

Generates a local notification if the server is turned off.

 

 

 

Remote login

 

Generates a local notification if a remote login occurs.

 

 

 

System tamper

 

Generates a local notification if the server covers are removed. This feature is not

 

 

available on all servers.

 

 

 

Event log 75% full

 

Generates a local notification if the event log reaches 75% of capacity.

 

 

 

Event log full

 

Generates a local notification if the event log is full. When the event log is full, the

 

 

oldest events are deleted.

 

 

 

Chapter 7. Configuring your Remote Supervisor Adapter using a text-based interface 83

Page 89
Image 89
IBM Partner Pavilion Remote Supervisor Adapter manual Press F3 and select Events For Local Notification, Local events