Note: The hard shutdown alert is sent only if a soft shutdown alert has not yet been sent.

5.Scroll down to the voltages section. The Remote Supervisor Adapter or ASM processor will send an alert if any monitored power source voltage falls outside its specified operational ranges.

If you click a voltage reading, a window similar to the one in the following illustration opens.

The Voltage Thresholds page displays the voltage ranges at which the Remote Supervisor Adapter or ASM processor reacts. The voltage threshold values are preset on the remote server and cannot be changed.

The ASM Web interface displays the voltage readings of the system board and the voltage regulator modules (VRM). The system sets a voltage range at which the following actions are taken:

Warning Reset

When the voltage drops below or exceeds the warning voltage range and then recovers to that range, the server or ASM processor assumes the voltage has returned to normal and no further alerts are generated.

Warning

When the voltage drops below or exceeds a specified voltage range, a voltage alert is sent to configured remote alert recipients. You must select the Voltage check box on the Alerts page for the alert to be sent.

Soft Shutdown

When the voltage drops below or exceeds a specified voltage range, a voltage alert is sent to configured remote alert recipients and the server begins the shutdown process with an orderly operating system shutdown. The server then turns itself off. You must select the Voltage check box on the Alerts page for the alert to be sent.

Hard Shutdown

When the voltage drops below or exceeds a specified voltage range,