Table 7. Port 1 settings (continued)

Field

What you type

 

 

Hangup string

Type the initialization string that will be used to instruct the modem to

 

disconnect. A default string is provided (ATH0). Do not change this string

 

unless your dial-out functions are not working properly.

 

 

Dial postfix string

Type the initialization string that is used after the number is dialed to tell

 

the modem to stop dialing. The default is ^M.

 

 

Modem query

Type the initialization string that is used to find out if the modem is

 

attached. The default is AT.

 

 

Factory settings

Type the initialization string that returns the modem to its factory settings

string

when the modem is initialized. The default is AT&F0.

 

 

Auto answer

Type the initialization string that is used to tell the modem to answer the

 

phone when it rings. The default is to answer after one ring or ATS0=1.

 

 

Escape string

Type the initialization string that returns the modem to command mode

 

when it is currently talking to another modem. The default is +++.

 

 

Auto answer

Type the initialization string that is used to tell the modem to stop

stop

answering the phone automatically when it rings. The default is ATS0=0.

 

 

Caller ID string

Type the initialization string that will be used to get caller ID information

 

from the modem.

 

 

Escape guard (0

Type the length of time before and after the escape string is issued to

- 250)

the modem. This value is measured in 10 millisecond intervals. The

 

default value is 1 second.

 

 

11. Click Save.

Initialization-string guidelines

If you need to provide a new initialization string, see the documentation that came with your modem. Your initialization string must contain commands that configure your modem as follows:

vCommand echoing OFF

vOnline character echoing OFF

vResult codes ENABLED

vVerbal result codes ENABLED

vAll codes and connect messages with BUSY and DT detection

vProtocol identifiers added — LAPM/MNP/NONE V42bis/MNP5

vNormal CD operations

vDTR ON-OFF hang-up, disable AA and return to command mode

vCTS hardware flow control

vRTS control of receive data to computer

vQueued and nondestructive break, no escape state

Note: The abbreviations in these commands have the following meanings:

AAauto answer

CD carrier detect CTS clear to send

DT data transfer

DTR data terminal ready

LAPM link access protocol for modems MNP microcom networking protocol RTS ready to send

Chapter 3. Configuring your Remote Supervisor Adapter or ASM processor 33