| Critical alerts | |
| Critical alerts are generated for events that signal that the server is no | |
| longer functioning. | |
Table 18. Critical remote alerts |
| |
|
|
|
Alphanumeric | Event | Action |
pager code |
|
|
|
|
|
00 | Temperature irregularity | Generates an alert if any of the monitored temperatures are outside |
|
| critical threshold values. Select Temperature Tables in the Temperature, |
|
| Voltage and Fan window to view the threshold values. If a critical |
|
| temperature condition is detected, the server automatically shuts down |
|
| and turns off. |
|
|
|
01 | Voltage irregularity | Generates an alert if the voltages of any of the monitored power supplies |
|
| fall outside their specified operational ranges. Select Voltage Tables in |
|
| the Temperature, Voltage and Fan window to view the threshold values. |
|
| If a critical voltage condition is detected, the server automatically shuts |
|
| down and turns off. |
|
|
|
02 | Tampering | Generates an alert if physical intrusion of the server box is detected. |
|
| Tamper monitoring is not available on some servers, in which case this |
|
| setting is ignored. |
|
|
|
03 | Multiple fan failure | Generates an alert if two or more of the cooling fans in the server fail. |
|
|
|
04 | Power failure | Generates an alert if any of the server power supplies fail. |
|
|
|
05 | Hard disk drive failure | Generates an alert if one or more of the hard disk drives in the server |
|
| fail. |
|
|
|
06 | VRM failure | Generates an alert if one or more voltage regulator modules (VRMs) fail. |
|
| VRMs are not used on some servers, in which case this setting is |
|
| ignored. |
|
|
|
| Reserved for future use. | |
|
|
|
| Warning alerts | |
| Warning alerts are generated for events that might progress to a | |
| critical/error level. | |
Table 19. Warning remote alerts |
| |
|
|
|
Alphanumeric | Event | Action |
pager code |
|
|
|
|
|
10 | Redundant power | Generates an alert if a redundant power supply fails. |
| supply failure |
|
|
|
|
11 | Single fan failure | Generates an alert if one fan fails. |
|
|
|
12 | Temperature irregularity | Generates an alert if any monitored temperatures are outside the |
|
| warning threshold values. Select Temperature Tables in the |
|
| Temperature, Voltage and Fan window to view the threshold values. |
|
| Unlike the critical temperature event, this event will not initiate system |
|
| shutdown. |
|
|
|
13 | Voltage irregularity | Generates an alert if any monitored voltages are outside the warning |
|
| threshold values. Select Voltage Tables in the Temperature, Voltage and |
|
| Fan window to view the threshold values. Unlike the critical voltage |
|
| event, this event will not initiate an automatic system shutdown. |
|
|
|
14 - 19 |
| Reserved for future use. |
|
|
|
Note: Hard disk drive Predictive Failure Analysis (PFA) alerts are not monitored.