Intermec 6400 manual Scan Options

Models: 6400

1 196
Download 196 pages 37.42 Kb
Page 91
Image 91

SECTION 3

Terminal Emulation Menu Screens

Scan Options

Use the Scan Options menu to designate how the hand-held computer handles scanned bar codes. The Scan Options menu is shown below. Descriptions of the options follow.

Scan Options

1)Redundancy

2)MOD 10 Check

3)Concatenate

4)BC Type Char

5)Stream Scan

6)Scan All Flds

7)More

Redundancy: This option requires two identical scans of a bar code, one right after another, before the hand-held com- puter accepts the scan as valid.

Mod 10 Check: When you select this option, a check digit is added at the end of the bar code after a good read. This is a variation of the modulus 10 formula and is used infre- quently.

For additional information on Mod10, refer to the book PEN*KEYR 6400 Programmers Reference Guide p/n:

977-054-004.

Concatenate: Each bar code read is added to the end of the previous bar code read until the computer meets a condition that forces transmission to the host.

When this option is OFF, each bar code read is placed at the beginning of the current input field. After a bar code is placed in a field, any subsequent read replaces the first read.

BC Type Char: This option adds a character associated with the bar code type at the beginning of the scanned bar code.

Stream Scan: If the scanned bar code is too big for the input field, the overflow information appears in the next field. This continues until the entire bar code is entered.

6400 Hand-Held Computer User’s Guide 3-19

Page 91
Image 91
Intermec 6400 manual Scan Options