REMOVAL PROCEDURE 1. Remove input power.
2. Perform the
. Monitor and Pedestal Removal rocedure
3. Perform the Case Cover Removal Procedure.
4. Locate the 5VDC Supply Module. See Figure F.23.
There are two supply modules located next Note: to each other. Make certain that you are
removing the correct module.
5. Using a small flathead screwdriver, remove leads 102A (white), 103B (pink/red) and the green ground lead from the bottom of the Supply Module. See Figure F.24.
6.Label and remove the positive and negative leads (81,81,50,50) from the top of the 5VDC Module using the small flathead screwdriver.
See Figure F.24.
7.Push down on the release tab and lift up to remove the 5VDC Supply Module from the DIN rail.