TROUBLESHOOTING AND REPAIR

F-5

 

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

(Continued)

 

POWER-UP PROBLEMS

If the correct input voltage is

 

 

 

 

 

 

 

 

 

 

 

 

being applied to the CPU and

 

 

 

 

 

the VRTEXTM 360 does not

 

 

 

 

 

power-up the CPU may be

 

 

The VRTEXTM

360 does not

Make certain the correct input

faulty.

 

 

 

With the ON Switch activated

 

 

power up when the ON Switch is

voltage is being applied to the

5VDC should be present at the

 

 

pushed. The green indicator light

VRTEXTM 360. (115-230VAC

Input Relay Coil.

Terminal A1

 

 

does come on but does NOT stay

single phase).

(Red Lead) to Terminal A2

 

 

on when the ON Switch is

 

(Black Lead). See the wiring

 

 

released.

 

 

diagram. If the green indicator

 

 

 

 

 

light is on the 5VDC should be

 

 

 

 

 

present at the relay coil.

 

 

 

 

 

Check for loose or faulty

 

 

 

 

 

connections between the Input

 

 

 

 

 

Relay, the Upper Terminal

 

 

 

 

 

Block and the ON Switch.

 

 

 

 

 

Check leads 101A and 103A.

 

 

 

 

 

See the wiring diagram.

 

 

 

 

 

If the 5VDC is being applied to

 

 

 

 

 

the Input Relay Coil and the

 

 

 

 

 

above mentioned connections

 

 

 

 

 

and leads are OK the Input

 

 

 

 

 

Relay Coil may be faulty.

 

 

 

 

 

Replace.

 

 

 

 

 

 

If the 5VDC is not present at

 

 

 

 

 

Terminals A1 to A2 check for

 

 

 

 

 

loose or faulty

connections

 

 

 

 

 

between the Input Relay Coil

 

 

 

 

 

and the CPU USB port. See

 

 

 

 

 

the wiring diagram.

 

 

 

 

 

The CPU may be faulty.

 