Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

F-12

TROUBLESHOOTING AND REPAIR

F-12

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

The

weld coupon image is a

Either the wrong coupon is on

N/A

 

 

 

FUNCTION PROBLEMS

 

 

different configuration than the

the stand or the wrong

 

 

physical coupon.

configuration as been selected

 

 

 

 

in the software.

 

 

 

 

 

Press the menu button and

 

 

 

 

select change coupon type.

 

 

 

 

Change the software selections

 

 

 

 

so that the images on the

 

 

 

 

screen match the hardware you

 

 

 

 

are using.

 

 

 

 

The arm and/or table are different

The software information may

N/A

 

than the visuals in the software.

be incorrect.

Press the menu

 

 

 

 

button and

select change

 

 

 

 

process. Make sure the images

 

 

 

 

on the screen match the

 

 

 

 

hardware being used.

 

 

When the check settings are

Check the settings in the

N/A

 

activated the incorrect settings

Instructor Mode.

 

 

 

appear.

Make sure all of the settings are

 

 

 

 

correct for the process and

 

 

 

 

parameters being used. Check

 

 

 

 

for the acceptable ranges for the

 

 

 

 

Lincoln defaults.

 

 

 

Holding the green button in does

To shut down the VRTEXTM 360

N/A

 

not shut down the VRTEXTM 360

select menu and then select

 

 

 

 

shutdown.

 

 

 

 

Sometimes the view in the helmet

Make sure the helmet is close to

Check for loose or faulty

seems to shake, wobble or jitter.

the work piece. The further the

connections on the VGA cable

 

 

helmet is from the work piece

between the Relay Board and

 

 

the more jitter there may be in

the Polhemus Interface Module.

 

 

the helmet display.

Also make

See the wiring diagram.

 

 

sure there are not other objects

Perform the

 

 

 

or frequencies

that are

Polhemus

 

 

interfering with the system.

Interface Module Test.

 

 

this manual.

 

 

 

 

 

 

See the Installation Section of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3878.

VRTEX TM 360

Page 69
Image 69
Lincoln Electric SVM200-A service manual See the Installation Section