Return to Section TOC Return to Master TOC
TROUBLESHOOTING AND REPAIR |
TABLE SWING ARM
REMOVAL AND REPLACEMENT PROCEDURE (continued)
FIGURE F.47 – “SOURCE’ CABLE CONNECTED TO POLHEMUS MODULE
Return to Section TOC Return to Master TOC
SOURCE
SYS
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
REMOVAL PROCEDURE 1. Remove input power.
2. Perform the
. Monitor and Pedestal Removal rocedure
3. Perform the Case Cover Removal Procedure.
4. Remove any coupons that are inserted into the swing arm.
5. Disconnect the cable labeled “SOURCE” from the polhemus module. See Figure F.47.
6. Remove the strain relief from the Table Swing Arm cable at the rear of the machine. See
Figure F.48.
7.Remove any cable ties.
8.Carefully slide the Table Swing Arm off of the top of the table mounting post.
9.Remove the plastic grommet from 1¾ “ access hole in case back. See Figure F.48.
10.Remove the Table Swing Arm cable through the case back via the 1¾” access hole.
VRTEX TM 360