TROUBLESHOOTING AND REPAIR

 

F-9

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

FUNCTION PROBLEMS

Check for loose or faulty con-

 

 

 

 

 

(Continued)

 

 

nections (ribbon cable)

 

 

 

between the User Interface

 

 

 

Digital I/O Module and the ter-

 

 

 

minal block interface. See

 

 

 

wiring diagram

 

The user is not receiving any

Make sure the Helmet (FMD) is

Check the USB connections

visual or audio

feedback

connected properly.

between

the

Polhemus

information in the helmet (FMD).

Check the USB connection

Interface Module and the CPU

 

 

between the Polhemus Interface

for loose or faulty connections.

 

 

Module and the CPU for loose

Make sure the FMD Control

 

 

or faulty connections.

Unit is are receiving the 5VDC

 

 

 

supply voltage. See the wiring

 

 

 

diagram.

 

 

 

 

 

Make sure the FMD Control

 

 

 

Unit is turned on.

 

 

 

 

If the 5VDC supply is not

 

 

 

present

perform

the 5VDC

 

 

 

Supply Test.

 

 

 

 

Perform the FMD Control Unit

 

 

 

Test.

 

 

 

 

 

The FMD may be faulty.

 

 

 

The CPU may be faulty.

Return to Section TOC Return to Master TOC

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3878.

VRTEX TM 360

Page 66
Image 66
Lincoln Electric SVM200-A service manual Supply Test Perform the FMD Control Unit