Return to Section TOC Return to Master TOC

F-110

RETEST AFTER REPAIR

F-110

ThisDESCRIPTIONprocedure will aid the technician in testing the basic operations of the VertexTM 360 after any repair or replacement procedure has been completed.

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

1.Make sure the stand, the monitor, the VR GMAW/FCAW gun and the VR SMAW device are properly connected to the unit and are not damaged.

2.Connect the external speakers if available.

3.Connect the machine to the 115 – 230VAC power source.

4.Using the green circular push button turn on the VertexTM360. Keep the button depressed for at least 3 seconds.

5.When the unit has “booted-up” proceed with login. See Operation Section of this manual.

6.Insert a USB memory device into the USB port on the front of the machine

7.Navigate through the following: See the of this manual.

a.OpSelectraticouponSection– must match actual coupon in arm.

b.Select 3/8 inch thickness.

c.Using the process selector switch select GMAW

d.Proceed with settings. See the Default Weld

Process Settings

8.Check the functionality of all the push buttons and lights. They must function as labeled. Listen for an audible signal when buttons are pressed.

9.Check the functionality of the VR GMAW/FCAW gun in all positions and with every coupon. When welding there must be visual and audio information in the helmet. If external speakers are used there must be audio information when welding.

10.Check all three different views using the right and left white screen select arrow keys.

11.Make certain that weld pass information can be saved in the USB memory device. See the

of this manual.Operation Section

12.Press the RED rectangular push button and then using the joystick select “Change Process”. Select “Yes”.

13.Navigate through the following: See the

Section of this manual.

a.SelectOperaticoupon – must match actual coupon in arm.

b.Select 3/8 inch thickness.

c.Using the process selector switch select VR SMAW

d.Proceed with settings. See the Default Weld

Process Settings

14.Check the functionality of the VR SMAW device in all positions and with every coupon. When welding there must be visual and audio information in the helmet. If external speakers are used there must be audio information when welding.

15.Physically rotate the stick device to 45 degrees position. The stick picture in the helmet must follow the actual movements.

16.Select “New Stick”. The physical stick should fully extend in the VR SMAW device. See the Operation Section of this manual.

17.Press the RED rectangular push button and then using the joystick select “Logout”. Select “Yes”. Login screen with keyboard appears.

18.Turn the key switch 90 degrees to the right. The instructor mode screen should appear. Check the update function for USB readiness.

19.Press the RED rectangular push button and then using the joystick select “Shutdown”. Select “Yes”.

VRTEX TM 360

Page 167
Image 167
Lincoln Electric SVM200-A service manual Retest After Repair, Process Settings, This manual.Operation Section