Return to Section TOC Return to Master TOC

F-28TROUBLESHOOTING AND REPAIRF-28

INTERFACE DIGITAL MODULE I/O TEST PROCEDURE (continued)

FIGURE F.7 – INTERFACE DIGITAL MODULE I/O LOCATION

Return to Section TOC Return to Master TOC

INTERFACE MODULE (USB)

INTERFACE MODULE DIGITAL I/O

HORIZONTAL

MOUNTING

SHELF

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

WARNING

ELECTRIC SHOCK can kill.

• Have a qualified individual install and service this equip- ment.

• Turn the input supply power OFF at the discon- nect switch or fuse box before working on this equipment.

• Do not touch electrically hot parts.

------------------------------------------------------------------

TEST PROCEDURE

1. Disconnect the input power.

2. Perform the

. Monitor and Pedestal Removal

3. Performrocedurethe.

4. Connect theCaseinput Covpower. Removal Procedure

5. Power up the machine.

6. Locate the Interface Digital Module I/O. See Figure F.7.

VRTEX TM 360