F-64

TROUBLESHOOTING AND REPAIR

F-64

12/15VDC SUPPLY MODULE REMOVAL AND REPLACEMENT PROCEDURE

(continued)

FIGURE F.25 – 12/15 VOLT SUPPLY MODULE LOCATION

12/15 VOLT SUPPLY

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

REMOVAL PROCEDURE 1. Remove input power.

2. Perform the

. Monitor and Pedestal Removal rocedure

3. Perform the Case Cover Removal Procedure.

4. Locate the 12/15VDC Supply Module. See Figure F.25.

There are two supply modules located next Note: to each other. Make certain that you are

removing the correct module.

5. Using a small flathead screwdriver, remove leads 102B (white), 103C (pink/red) and the green ground lead from the bottom of the 12/15VDC Supply Module. See Figure F.26.

6.Label and remove the positive and negative leads (71, 71, 72, 72) from the top of the Supply Module using the small flathead screwdriver.

See Figure F.26.

7.Push down on the release tab and lift up to remove the 12/15VDC Supply Module from the DIN rail.