Maintenance of the NT631/NT631C

Section 7-3

6.Fit new backlights.

The backlight for the top is different from that for the bottom.

Fit projections and dents of the backlight with those on the fixture, and shift the backlight to the left. Check that the backlight is in contact with the left end of the fixture and the cable comes out from the notch without being trapped.

When the backlight is correctly fit, tighten the screws at a torque of 0.1 N·m.

Top part

Bottom part

Fixture

 

 

Backlight fixture on the PT

Backlight

Mounting screw

Cable

 

 

Backlight

Cable

Backlight fixture on the PT

Mounting screw

Backlight

 

Fixture

 

 

Backlight

7.Engage backlight connectors at the top and the bottom respectively in place. The backlight cable has a polarity; refer to the figure below.

White Red

RedWhite

8.Fit two touch panel cables at the top. Be sure to lock the connectors as in step 4 after fitting.

9.Close the rear case, and tighten four screws. Make sure that the internal cable is not trapped.