Setting the Bar Code Reader Input Function

Section 6-10

Setting the

Communications

Conditions and Setting

Method

Set the bar code reader communications conditions and method of confirma- tion at input by following the menu operation from the System Menu shown below.

Ver 4.12

Select Maintenance Mode.

Select Memory Switch.

Press [] (next screen) or [] (previous

screen) to display the fourth memory switch setting screen.

Press Comm. A Method to select Bar-Code Reader.

The setting option changes each time the touch switch is pressed.