Programming Console Function

Section 6-12

CQM1: @@@3, @@@4, @@@5, @@*6

where * is a number in the range 1 to 9 or the letter X or Y.

C200HX/HG/HE: @@@5 @@*6

where * is a number in the range 1 to 9 or the letter X or Y.

6-12-2 Connection Method

CQM1, CQM1H, C200HX/

The connection method is exactly the same as for the NT Link (1:1). Refer to

HG/HE(-Z)E, or SRM1

SECTION 4 Connecting to the Host from the RS-232C Port or SECTION 5

 

Connecting to the Host from the RS-422A/485 Port for details on connecting

 

to the PLC.

 

* When using the Programming Console function with a CQM1H, turn ON pin

 

7 of the DIP switch on the front of the CQM1H’s CPU Unit.

CPM1 or CPM2A

The connection method is the same as for the NT Link (1:1). With a CPM1,

 

connect the RS-232C cable to the peripheral port via a CPM1-CIF01 RS-

 

232C Adapter or CPM1-CIF11RS-422A Adapter.

 

Refer to SECTION 4 Connecting to the Host from the RS-232C Port or SEC-

 

TION 5 Connecting to the Host from the RS-422A/485 Port for details on con-

 

necting to the PLC.

CPM2C

The connection method is the same as for the NT Link (1:1). Connect to the

 

PLC’s communications connector with a CPM2C-CN111 or CS1W-CN114/

 

118 Connecting Cable, a CPM1-CIF01RS-232C Adapter, or a CPM1-CIF11

 

RS-422A Adapter.

 

Refer to SECTION 4 Connecting to the Host from the RS-232C Port or SEC-

 

TION 5 Connecting to the Host from the RS-422A/485 Port for details on con-

 

necting to the PLC.

 

* When using the Programming Console function with a CPM2C, turn ON pin

 

2 of the DIP switch on the front of the CPM2C’s CPU Unit.

CS/CJ-series PLC

The connection method is exactly the same as for the NT Link (1:N) (standard

 

or high-speed). Refer to SECTION 4 Connecting to the Host from the RS-

 

232C Port or SECTION 5 Connecting to the Host from the RS-422A/485 Port

 

for details on connecting to the PLC. The standard or high-speed 1:N NT Link

 

can be used.

 

The Programming Console function can be used only when the PT’s unit num-

 

ber is set to 0. Only one Unit using the Programming Console function can be

 

connected to each of the PLC’s ports (built-in RS-232C port and peripheral

 

port).

 

Make sure that the PT’s highest unit number is set to 0 in the CS/CJ-series

 

PLC setup.

 

With the CS/CJ-series PLC, the Programming Console function can not be

 

used simultaneously at both the built-in RS-232C port and peripheral port.

 

Furthermore, the Programming Console function can not be started at the

 

RS-232C port while a Programming Console is connected to the peripheral

 

port.