Connecting to the Host’s RS-422A/485 Port

Section 5-2

Connecting between NT631/NT631C Units

NT631/NT631C

Host

 

RS-485

NT631/NT631C side

NT631/NT631C side

RDA

TRM

RDB

SDA

SDB

RSA

RSB

RS-422A/ 485 terminal block

Short-circuit tool

Abbreviation

RDA (-)

 

 

TRM

 

 

 

 

 

 

RDB (+)

 

 

 

 

 

 

SDA (-)

 

 

 

 

 

 

SDB (+)

 

 

 

 

 

 

RSA (-)

 

 

RSB (+)

 

 

 

 

 

 

 

 

Functional

 

 

ground

 

 

Shielding wire

Abbreviation

RDA (-)

TRM

RS-422A/

RDB (+) 485 terminal

SDA (-) block SDB (+)

RSA (-)

RSB (+)

Functional ground

RDA

TRM

RDB

SDA

SDB

RSA

RSB

24V

+DC

24V

+DC

Connecting an NT631/ NT631C and a Host

*Short TRM and RDA terminals of the NT631/NT631C at the end of the RS- 485 cable (* marked in the above figure) using the short-circuit tool sup- plied with the NT631/NT631C.

For details on handling shield wires, refer to 5-2-8 Handling the Shield on RS- 422A/485 Cables on page 125.

The relay terminal block is not included in this figure. Insert the relay terminal block so as to achieve the wiring configuration shown below.

NT631/NT631C

Host

RS-485

Wiring When Connecting a CS-series Serial Communications Board, CS/ CJ-series Serial Communications Unit, C-series C200HX/HG/HE(-Z)E Communications Board, or CQM1H Serial Communications Board

Applicable Units:

CS1W-SCU31-V1

CJ1W-SCU31-V1/CJ1W-SCU41(-V1)

CS1G-CPU42/43/44/45-E(V1)

CS1H-CPU63/64/65/66/67-E(V1)

CS1G-CPU42H/43H/44H/45H

CS1H-CPU63H/64H/65H/66H/67H

CS1D-CPU66H/67H (See note.)

122

Page 139
Image 139