Connecting to the Host’s RS-232C Port

Section 5-1

Wiring for a Memory Link Connection

Prepare the adapter cable while referring to the diagram shown below.

 

NT-AL001 side

 

1

6

Abbreviation

Pin number

 

 

 

 

 

 

FG

Connector

 

 

 

hood

 

 

 

 

 

 

 

1

 

 

RS-232C

SD

2

 

 

RD

 

 

 

connector

3

 

 

 

RS

4

 

 

 

CS

5

 

 

 

+5V

6

 

 

 

 

 

 

 

8

 

 

 

SG

9

 

 

(9-pin type)

Shielding wire

5

9

No +5 V output is at the host side

 

 

 

Host side

Abbreviation

Connector hood

SD

RS-232C

RD connector

RS

CS

+5V

SG

A +5 V output is present at the host side

Since it is necessary to input a voltage of +5 V to the number 6 pin of NT- AL001, supplying a voltage of 5 V from the host or an external voltage supply for NT-AL001 is required.

5-1-3 1:N Connection between RS-422A/485 at the PT and RS-232C at the Host

The connection method in which the RS-422A/485 ports of multiple NT631/ NT631Cs are connected to the RS-232C port of one host in a 1:N connection is described here.

An RS-232C/RS-422A Adapter (NT-AL001) is used to convert between the

RS-232C and RS-422A/485 communications methods.

RS-422A/485 cable (max. total length: 500 m)

NT631/NT631C

NT631/NT631C

Host Link Unit or CPU Unit

CS/CJ-series PLC,

C200HX/HG/HE(-Z)E

RS-232C/RS-422A

convertor unit9-pin connector (NT-AL001)

 

RS-232C cable with

 

connectors

RS-422A terminal

9-pin connector

block

 

Serial port B (RS-422A/485, terminal block)

NT631/NT631C