Device Monitor Function

Section 6-13

CPM1, CPM2A, or SRM1

The 1:1 NT Link can be used in all CPU Units and the 1:N NT Link can also be

 

used in -V2 and higher versions of the SRM1. The connection method is

 

exactly the same as for the 1:1 NT Link or 1:N NT Link. With a CPM1, connect

 

the RS-232C cable to the peripheral port via a CPM1-CIF01RS-232C

 

Adapter or CPM1-CIF11RS-422A Adapter.

 

Refer to SECTION 4 Connecting to the Host from the RS-232C Port or SEC-

 

TION 5 Connecting to the Host from the RS-422A/485 Port for details on con-

 

necting to the PLC.

CPM2C

The 1:1 NT Link can be used. The connection method is the same as for the

 

NT Link (1:1). Connect to the PLC’s communications connector with a

 

CPM2C-CN111 or CS1W-CN114/118 Connecting Cable, a CPM1-CIF01 RS-

 

232C Adapter, or a CPM1-CIF11RS-422A Adapter.

 

Refer to SECTION 4 Connecting to the Host from the RS-232C Port or SEC-

 

TION 5 Connecting to the Host from the RS-422A/485 Port for details on con-

 

necting to the PLC.

CS/CJ-series PLC

The 1:N NT Link (standard or high-speed) can be used. The connection

 

method is exactly the same as for the 1:N NT Link.

 

Refer to SECTION 4 Connecting to the Host from the RS-232C Port or SEC-

 

TION 5 Connecting to the Host from the RS-422A/485 Port for details on con-

 

necting to the PLC.