Functions of the NT631/NT631C

 

Section 1-2

Mark

Image data

Library data

Lamps

These are graphics whose display status changes in accordance with the

 

states of bits at the host. Squares, circles, sectors and polygons can be used

 

for lamps (normal (standard) lamps). In accordance with the status of the host

 

bit, they can be lit (displayed in reverse video) or flashed (repeated alternation

 

between normal and reverse video display states).

 

Lamps can also display different image/library data for the ON and OFF states

 

of the host bit (such lamps are called image/library lamps).

 

There are four standard lamp labels: fixed display character strings, ON/OFF

 

switching character strings, numeral displays, and character string displays.

 

When fixed display character strings or ON/OFF switching character strings

 

are used, several lines of labels can be displayed.

 

Normal (Standard) Lamps

 

 

ON

 

ON

 

 

 

 

 

Host

 

 

 

 

 

Unlit state

 

 

 

Lit state

Image/Library Lamps

ON

Unlit state

Host

Lit state

Touch Switches

These switches can be set at any location on the screen. Pressing a touch

 

switch on the screen where a touch switch has been set can have the follow-

 

ing effects:

 

Notification to a host bit (input notification function)

 

Changing the displayed screen (screen switching function)

 

Input of a numeric value or character string (input key function)

 

Copying of a numeric value or character string (copy key function)

 

Shifting to another numeric value or character string input field (cursor

 

moving key function)

 

Obtaining a hard copy of the screen (screen print function)

 

Opening / Closing a window

 

Moving a window

 

Touch switches can be made to light or flash in accordance with the status of

 

a host bit in the same way as lamps.

 

The following 8 types of display graphic can be used for touch switches:

13

Page 30
Image 30