Connecting to the Host’s RS-422A/485 Port

Section 5-2

5-2-4 1:N Connection among RS-422A Ports

The connection method in which the RS-422A ports of multiple NT631/

NT631Cs and one host are connected in a 1:N connection is described here.

CPU Unit

CS/CJ-series PLC,

C200HX/HG/HE(-Z)E

9-pin connector

RS-422A cables

(max. total length 500 m)

NT631/NT631C

Serial port B

(RS-422A/485, terminal block)

NT631/NT631C

NT631/NT631C

Reference: • Communications using the RS-422A standard NT link (1:N) method is possible only when a Serial Communications Board is installed in a CS- series PLC, a Serial Communications Unit is installed in a CS/CJ-series PLC, a Communications Board is installed in a C200HX/HG/HE(-Z)E, or a CQM1H-SCB41 Serial Communications Board is installed in a CQM1H.

Communications using the RS-422A high-speed NT link (1:N) method is possible only when a Serial Communications Board is installed in a CS- series PLC or a Serial Communications Unit is installed in a CS/CJ-series PLC.

119