SpecificationsAppendix A

For an NT Link, 1:N, RS-422A/485

Item

Specification

 

 

Communications standard

EIA RS-422A/485

 

 

Connector

Terminal block

 

 

Number of Units connected

1:1 to 8

 

 

Transmission distance

Max. 500 m

 

 

For a High-speed NT Link, 1:N, RS-232C

Item

Specification

 

 

Communications standard

EIA RS-232C

 

 

Connector

9-pin D-SUB connector (female) (serial port A, B)

 

 

Number of Units connected

1:1 to 8

 

 

Transmission distance

Max. 15 m*

*To connect two or more PTs, NT-AL001 Adapters are required. When using an NT-AL001, the specifications are as follows.

RS-232C cable: Max. 2 m

RS-422A/485 cable: Total length 500 m max.

For a High-speed NT Link, 1:N, RS-422A/485

Item

Specification

 

 

Communications standard

EIA RS-422A/485

 

 

Connector

Terminal block (serial port B)

 

 

Number of Units connected

1:1 to 8

 

 

Transmission distance

Max. 500 m

 

 

For a Memory Link, RS-232C

Item

 

Specification

 

 

 

Communications standard

EIA RS-232C

 

 

 

 

Communications settings

Start-stop synchronization

 

 

Communications speed:

1200, 2400, 4800, 9600, 19200, 38400bps

 

Data length:

7, 8 bits

 

Stop bit:

1, 2 bits

 

Parity:

None, even, odd

 

Flow control:

None, RS/CS, XON/XOFF

 

Response:

Presence/absence

 

 

Connector

9-pin D-SUB connector (female) (serial port A, B)

 

 

 

Number of Units connected

1:1

 

 

 

 

Transmission distance

Max. 15 m*

 

 

 

 

Communications protocol

Memory link

 

 

 

 

* When using NT-AL001, specification is as follows:

RS-232C:

Max. 2 m

RS-422A:

Max. total length 500 m

252

Page 269
Image 269
Omron NT631C manual For an NT Link, 1N, RS-422A/485, For a High-speed NT Link, 1N, RS-232C, For a Memory Link, RS-232C