Operations in the System Installer Mode

Section 6-5

Change the system settings by following the menu operation from the System

Installer mode menu shown below.

Select Change System Settings.

Select Display System Menu or Screen Memory Protect.

Each time either of these items is selected, the setting switches from Disabled to Enabled or vice versa.

Select OK.

The settings are written to the NT631/NT631C while the screen is displayed.

If Cancel is selected, the NT631/NT631C returns to the System Installer mode menu without changing the settings. The settings remain as they were before the operation was started.

If writing of the settings fails, a screen asking whether you wish to try again is displayed.

After the settings have been written, the System Installer mode menu screen is redisplayed.

6-5-4 Clearing Screen Data

If the screen data has been corrupted and the NT631/NT631C cannot be started normally, use this function to clear the screen data.

Note that only the screen data is cleared (initialized), and the memory switch settings and the display history/alarm history record data are retained.

Reference: • When this function is used, all of the screen data contents registered in the NT631/NT631C up to that point are cleared. Check that the created screens are backed up at the Support Tool before using it.

• The screen data can also be cleared from the System Menu (page 135).

148

Page 165
Image 165
Omron NT631C manual 148