Power-On-Self-Test (POST)
The POST diagnostic program performs the following basic tests:
•checksum tests on the Boot firmware located in a PROM and the main Switch firmware located in FLASH memory
•functional hardware tests on internal Switch memory
•various read/write register and loopback
•Frame Bus and Auto Route logic tests
•
•Switch Management port logic
•Arbitrated Loop tests
Heartbeat LED Blink Patterns
Normal (all pass)
If all POST diagnostics pass, the Switch will go to normal operation and the Heartbeat LED will blink at a steady rate of one (1) blink per second.
1 sec.
Failure Blink Patterns
The Heartbeat LED indicates the error by blinking a series of blinks, pausing for three seconds, then repeating the blinks. The number of blinks between the three- second pauses indicates the error. The blinks are at about twice the speed of the normal Heartbeat.
Failure blink pattern | Repeat pattern |
(In this example it is 4) |
|
1 sec.
3 sec. pause
Test/Failure Descriptions
The following paragraphs describe the tests and their failure indication. If any
POST errors occur, notify Ancor Customer Service or your authorized
maintenance provider. Refer to Appendix B for information about how to contact Ancor Customer Service.
GigWorks | Diagnostics/Troubleshooting | |
Installer's/User's Manual |