Image 127

 

Reference Information

 

 

Switch Environmental

 

Operational Temperature:

10 to 40°C (50 to 104°F)

Operating Humidity:

25 to 80%, non-condensing

Operating Altitude:

0 to 3048m (0 to 10,000 feet)

Operating Vibration:

During/after (in any axis) of magnitude:

 

2.54mm (0.1”) from 5 to 14 Hz

 

0.1G from 14-300 Hz

Operating Shock:

During/after (in any axis) of magnitude:

 

1.0G for 15 m seconds

Air flow:

Cooling air flows from the front to the back.

Heat output:

600 BTU/hr fully populated

Non-Operational Temperature:....

-40 to 65°C ( -40 to 149F)

Non-Operating Humidity:

25 to 90%, non-condensing

Non-Operating Altitude:

0 to 15240m (0 to 50,000 feet)

Non Operating Vibration:

(In any axis): 0.5G from 10 to 300 Hz

Non Operating Shock:

(In any axis): 8.0G for 15 m seconds

Switch Regulatory Certifications

 

Safety Standards:

UL1950

 

CSA 22.2 No. 950

 

EN60950

Emissions Standards:

FCC Part 15B Class A

 

VCCI Class A ITE

 

CISPR 22, Class A

 

EN 55022, Class A

Voltage Fluctuations:

EN 61000-3-3

Harmonics:

EN 61000-3-2

Immunity:

EN 50082-1:1997

Marking:

FCC Part 15

 

UL (United States)

 

UL (Canada)

 

TUV

 

VCCI

 

CE