Power-On-Self-Test (POST)

Switch Auto-Route Test Failure (10 Blinks)

The Switch is operable. The Switch Auto-Route Test verifies the auto-route capability of individual ports to automatically route frames to the other ports in the chassis. A failure indicates an inability to successfully route frames between a port pair and blinks the Heartbeat LED ten times between three-second pauses. The Switch disables the failing ports or port-pairs and blinks their Logged-in LEDs.

The ports whose Logged-in LEDs are not blinking have passed the test and are all useable.

Switch Class 1 Connection Test Failure (11 Blinks)

The Switch is operable. The Switch Class 1 Connection Test verifies the ability to perform software controlled Class 1 connections between port-pairs, to pass frames through the connections, and to perform software controlled disconnects. A failure indicates an inability to perform a Class 1 connection between a port pair and blinks the Heartbeat LED eleven times between three-second pauses. The Switch disables the failing ports or port-pairs and blinks their Logged-in LEDs.

The ports whose Logged-in LEDs are not blinking have passed the test and are all useable.

Switch Auto Connect Test Failure (12 Blinks)

The Switch is operable. The Switch Auto Connection test verifies the ability to perform automatic (or hardware controlled) Class 1 connections between ports, to pass frames through the connection, and to perform an automatic disconnect between the port pair. A failure indicates an inability to perform an automatic Class 1 connection between a port pair and blinks the Heartbeat LED 12 times between three-second pauses. The Switch disables the failing ports or port-pairs and blinks their Logged-in LEDs.

The ports whose Logged-in LEDs are not blinking have passed the test and are all useable.

Arbitrated Loop Test Failure (13 Blinks)

The Switch is operable. The Arbitrated Loop test verifies the ability of the Arbitrated Loop ports to initialize properly. A failure indicates the inability to successfully initialize an Arbitrated Loop (FL) port and blinks the heartbeat LED 13 times between three-second pauses. The Switch disables the failing ports and blinks their Logged-in LEDs.

The ports whose Logged-in LEDs are not blinking have passed the test and are all useable.