Chapter 4 Configuration Installation and Operation Manual
4-22 Configuring IPmux-11 for Operation IPmux-11 Ver. 2.00
Sensitive (Whether to optimize the clock for accurateness or for constant
delay):
Data (Accurate clock is more important than constant delay.
Delay (Constant delay is more important than accurate clock.
VLAN Tagging:
Enable (VLAN tagging is enabled)
Disable (VLAN tagging is disabled)
VLAN ID: 1–4095
VLAN priority: 0–7
IP TOS (IP ToS field in the IP frames transmitted by IPmux-11. ToS
configuration configures the WHOLE byte, since different vendors may use
different bits to tag packets for traffic prioritization. ToS assignment applies
to all TDM packets leaving IPmux-11.): 0–255
Payload Format (TDMoIP format):
V1 (Version 1)
V2 (Version 2)
When PSN Type is MPLS/ETH the payload format is always V2.
Make sure that selected VLAN is configured as a member of the network port
VLANs (see Configuring the Ethernet Bridge below).
7. Type S to save the changes.
Configuration>Connection
1. Bundle ID[1 - 1] ... (1)
2. Connection mode > (TDMoIP CE)
3. PSN type > (UDP/IP)
4. DS0 bundle []>
5. Bundle connection >
>
Please select item <1 to 5>
ESC-prev.menu; !-main menu; &-exit 1 Mngr/s
Figure 4-19. Connection Menu
Note