Chapter 4 Configuration Installation and Operation Manual
4-20 Configuring IPmux-11 for Operation IPmux-11 Ver. 2.00
Configuring Bundle Connections
IPmux-11 supports one bundle that can include up to 31 E1 or up to 24 T1
timeslots. The bundle can be connected to any bundle of the TDMoIP device that
operates opposite IPmux-11. Currently, TDMoIP traffic is sent and received via the
network port only.
To configure bundle connection:
1. From the Configuration menu, select Connection.
The Connection menu appears (see Figure 4-19).
2. Select DS0 bundle.
The DS0 Bundle menu appears (see Figure 4-20).
3. From the DS0 Bundle, assign timeslots to the current bundle (1) by selecting a
timeslot and choosing 1 (assigned) or 0 (not assigned).
You can assign all timeslots to the current bundle at once by typing E.
You can cancel assignment of all timeslots to the current bundle at once by
typing L.
4. From the Connection menu, configure the PSN Type:
UDP/IP (bundle encapsulation is UDP/IP)
MPLS/ETH (bundle encapsulation is MPLS (Multi-Protocol Label Switching)
/ Ethernet)
PSN Type is only available after Bundle ID has been set.
5. From the Connection menu, select Bundle connection.
The Bundle Connection menu appears (see Figure 4-21 and Figure 4-22).
IPmux-11 only shows the relevant menu options, depending on the connection
mode and PSN type.
6. From the Bundle Connection menu, configure the following (if it appears in
the menu):
Destination IP Address (IP address of the destination device): 0.0.0.0 to
255.255.255.255.
Outbound Label Tagging:
Enable (Outbound labels are enabled)
Disable (Outbound labels are disabled)
Outbound tunnel label (MPLS transmit label): 0–1048576
Outbound EXP bits (MPLS label exp bits): 0–7
Inbound label tagging:
Enable (Inbound labels are enabled)
Disable (Inbound labels are disabled)
Inbound tunnel label (MPLS receive label): 0–1048576
Note
Note