Chapter 4 Configuration | Installation and Operation Manual |
|
|
Rx sensitivity (Maximum attenuation of the receive signal that can be compensated for by the interface receive path):
Short haul (-10 dB) Long haul (-32 dB)
Trail Mode (Enables the
Termination
Extension
Line type (E1 framing mode):
Unframed G.703 (Framing is not used)
Framed G.704 (G.704 framing,
Framed MF CRC4 (CAS enabled,
Idle Code (code transmitted to fill unused timeslots in the E1 frames): 00 to ff.
4.If you configure the Line type to Framed MF or Framed MF CRC4, type N to display the next page of E1 parameters (Figure
Send Upon Fail (Notification sent to the E1 side if Ethernet link fails):
OOS Code
OOS code (Code to be sent to the E1 side if Ethernet link fails):
OOS signaling
Space (Code specified by the Space Signaling Code parameter is sent) Mark (Code specified by the Mark Signaling Code parameter is sent)
Space Mark (Space code is sent in the first 2.5 seconds, then mark code is sent)
Mark Space (Mark code is sent in the first 2.5 seconds, then space code is sent)
Mark signaling code:
Space signaling code:
5. Type S to save the changes.
Configuring |