Installation and Operation Manual Chapter 1 Introduction
IPmux-11 Ver. 2.00 Technical Specifications 1-25
Timing Transmit Internal
External input or output via dedicated connector:
E1/T1 or 2048/1544 kHz squarewave (RS-485
electrical levels)
Loopback
Adaptive
Pseudowire
Connections
Number of
Connections
1
Jitter Buffer Size 3–300 msec with 1 msec granularity
Management Methods SNMPv1
Telnet
RADview Service Center TDMoIP (ordered separately)
ASCII terminal via V.24 (RS-232) DCE port
Diagnostics Loopbacks E1/T1 local loopback
E1/T1 remote loopback
T1 Facility Type 1 (FAC1) in-band remote loopback
Statistics E1/T1 As per G.826 and RFC 2495
Ethernet As per RFC 2819
Receive Buffer
Indication
Overflow, underflow, sequence error
Indicators General PWR (green) – Power status
ALM (red/yellow) – Alarm status
EXT CLK (red/green) – External clock status
E1 E1 SYNC (red/green) – E1 synchronization
T1 T1 SYNC (red/green) – T1 synchronization
Ethernet LINK/ACT (green) – Link/activity status
Power AC/DC Source 100–240 VAC or -40/-60 VDC
Power
Consumption
8W max
Physical Height 43.7 mm (1.72 in)
Width 217 mm (8.55 in)
Depth 170 mm (6.7 in)
Weight 0.5 kg (1.1 lb)
Environment Temperature 0°C to 50°C (32°C to 122°F)
Humidity Up to 90%, non-condensing