Installation and Operation Manual

 

 

 

Chapter 1 Introduction

 

 

 

 

 

 

Timing

Transmit

Internal

 

 

 

 

External input or output via dedicated connector:

 

 

 

E1/T1 or 2048/1544 kHz squarewave (RS-485

 

 

 

electrical levels)

 

 

 

Loopback

 

 

 

 

Adaptive

 

 

Pseudowire

Number of

1

 

 

 

Connections

Connections

 

 

 

 

 

Jitter Buffer Size

3–300 msec with 1 msec granularity

Management

Methods

SNMPv1

 

 

 

 

Telnet

 

 

 

 

RADview Service Center TDMoIP (ordered separately)

 

 

ASCII terminal via V.24 (RS-232) DCE port

Diagnostics

Loopbacks

E1/T1 local loopback

 

 

 

E1/T1 remote loopback

 

 

T1 Facility Type 1 (FAC1) in-band remote loopback

Statistics

E1/T1

As per G.826 and RFC 2495

 

Ethernet

As per RFC 2819

 

 

Receive Buffer

Overflow, underflow, sequence error

 

Indication

 

 

 

 

Indicators

General

PWR (green) – Power status

 

 

ALM (red/yellow) – Alarm status

 

 

EXT CLK (red/green) – External clock status

 

E1

E1 SYNC (red/green) – E1 synchronization

 

T1

T1 SYNC (red/green) – T1 synchronization

 

Ethernet

LINK/ACT (green) – Link/activity status

Power

AC/DC Source

100–240 VAC or -40/-60 VDC

 

Power

8W max

 

 

 

Consumption

 

 

 

 

Physical

Height

43.7 mm (1.72 in)

 

 

Width

217 mm (8.55 in)

 

 

Depth

170 mm (6.7 in)

 

Environment

Weight

 

0.5 kg (1.1 lb)

 

 

0 C to 50 C (32 C to 122 F)

 

Temperature

°

°

°

°

 

Humidity

Up to 90%, non-condensing

IPmux-11 Ver. 2.00

Technical Specifications

1-25

Page 39
Image 39
RAD Data comm IPmux-11 Number, Connections Jitter Buffer Size Msec with 1 msec granularity, Height, Width, Depth