Installation and Operation Manual

Chapter 4 Configuration

 

 

Configuring IPmux-11 at the Physical Level

The TDM (E1 or T1) and Ethernet interfaces of IPmux-11 must be configured at the physical level.

Configuration>Physical layer

 

1.

TDM

>

2.

Eth

>

3.

External clock interface

(Balance)

>

 

Please select item <1 to 3>

 

ESC-prev.menu; !-main menu; &-exit

1 Mngr/s

Figure 4-13. Physical Layer Menu

Configuring the E1 TDM Interface

The E1 and T1 interfaces of IPmux-11 are configured via the TDM menu. IPmux-11 automatically detects whether the interface is E1 or T1, and displays the appropriate menu.

To configure the E1 interface:

1.From the Configuration menu, select Physical layer. The Physical Layer menu appears.

2.From the Physical Layer menu, select TDM.

The TDM (E1) menu appears (see Figure 4-14).

3.From the TDM (E1) menu, configure the following: Admin Status:

Enable (E1 link is enabled) Disable (E1 link is disabled)

Transmit clock source:

Adaptive (Adaptive clock regeneration)

Loopback (E1 recovered Rx clock is used as the Tx clock) Internal (Tx clock is received from an internal oscillator) System (System clock is used as the Tx clock)

IPmux-11 Ver. 2.00

Configuring IPmux-11 for Operation

4-13

Page 71
Image 71
RAD Data comm operation manual Configuring IPmux-11 at the Physical Level, Configuring the E1 TDM Interface