Chapter 4 Configuration

Installation and Operation Manual

 

 

Enable (Telnet, SNMP or Web access is enabled) Disable (Telnet, SNMP or Web access is disabled)

Manager Only (Access is allowed only for the stations appearing in the manager list).

Table 4-1. Management Access Implementation

Access Method

Mode

Who is Allowed to Access IPmux-11

 

 

Network

 

 

 

Network

 

 

Manager(s)

Manager(s) not

 

 

Defined

Defined

 

 

 

 

 

Enable

Anybody

Anybody

 

 

 

 

SNMP Access

Disable

Nobody

Nobody

 

 

 

Manager Only

Only defined

Nobody

 

 

 

network managers

 

 

 

 

 

 

Enable

Anybody

Anybody

 

 

 

 

Telnet Access

Disable

Nobody

Nobody

 

 

 

Manager Only

Only defined

Anybody

 

 

 

network managers

 

 

 

 

 

 

Enable

Anybody

Anybody

 

 

 

 

Web Access

Disable

Nobody

Nobody

 

 

 

Manager Only

Only defined

Anybody

 

 

 

network managers

 

 

 

 

 

Configuration>System>Management>Management Access

1.

User Access

>

 

2.

TELNET access

>

(Enable)

3.

SNMP access

>

(Disable)

4.

WEB access

>

(Enable)

>

 

 

 

ESC-prev.menu; !-main menu; &-exit

 

1 Mngr/s

Figure 4-10. Management Access Menu

Configuring Control Port Parameters

Configuration parameters of the IPmux-11 control port, except for the baud rate are set at the factory and cannot be changed by the user (see Figure 4-11). These parameters have the following values:

Data bits – 8

Parity – None

Stop bits – 1

Flow control – None.

4-10

Configuring IPmux-11 for Management

IPmux-11 Ver. 2.00

Page 68
Image 68
RAD Data comm IPmux-11 operation manual Configuring Control Port Parameters, Management Access Implementation