Chapter 6 Troubleshooting and Diagnostics | Installation and Operation Manual | |
|
|
|
|
|
|
|
|
|
6.4 Troubleshooting
The following table presents the event types as they appear on the Event Log File and lists the actions required to correct the event (alarm) indication.
Table 6-4. IPmux-11 Troubleshooting Chart
Fault | Probable Cause | Remedial Action | |
|
|
|
|
E1/T1 equipment | Configuration or physical layer | 1. | Check cables and physical |
connected to | problems |
| connectivity. |
not synchronized with |
| 2. | Check |
| |||
|
| configuration and, if necessary, | |
|
|
| |
|
|
| other |
|
| 3. | Check E1/T1 physical connection |
|
|
| (use loopbacks). |
|
|
|
|
Slips and errors in E1/T1 | • Ethernet port in switch and | 1. | Check E1/T1 physical connection |
equipment |
| (use loopbacks). | |
| rate or duplex mode | 2. | Check timing settings according to |
|
| ||
| • Ethernet port is set to work in |
| explanation in this manual. |
| half duplex mode (may cause | 3. | Check switch and |
| extreme PDV because of | ||
|
| configuration (negotiation, rate, | |
| collisions and backoffs) |
| |
|
| duplex mode). | |
|
|
| |
| • Timing configuration is not | 4. | Check PDV introduced by the |
| properly set (periodic buffer | ||
|
| network, and, if necessary, increase | |
| under/overflows shown on IP |
| |
|
| PDVT jitter buffer setting.. | |
| channel status menu) |
| |
|
|
| |
| • Network PDV or lost frames |
|
|
|
|
|
|
Echo in voice | High delay in voice path | 1. | Check network delay and try to |
|
|
| decrease it. |
|
| 2. | Try to decrease PDVT (jitter) buffer. |
|
|
|
|
Troubleshooting |