Roland XV-88 owner manual 276, Data set 1DT1 12H

Models: XV-88

1 312
Download 312 pages 6 Kb
Page 276
Image 276

MIDI Implementation

Data set 1DT1 (12H)

Status

Data byte

Status

F0H

41H, dev, 00H, 10H, 12H, aaH, bbH,

F7H

 

ccH, ddH, eeH, ... ffH, sum

 

Byte

Explanation

 

F0H

Exclusive status

 

41H

ID number (Roland)

 

dev

Device ID (dev: 00H - 1FH, Initial value is 10H)

00H

Model ID #1 (XV-88)

 

10H

Model ID #2 (XV-88)

 

12H

Command ID (DT1)

 

aaH

Address MSB: upper byte of the starting address of the data to be sent

bbH

Address: upper middle byte of the starting address of the data to be

 

sent

 

ccH

Address: lower middle byte of the starting address of the data to be

 

sent

 

ddH

Address LSB: lower byte of the starting address of the data to be sent.

eeH

Data: the actual data to be sent. Multiple bytes of data are transmitted

 

in order starting from the address.

 

:

:

 

ffH

Data

 

sum

Checksum

 

F7H

EOX (End Of Exclusive)

 

*The amount of data that can be transmitted at one time depends on the type of data, and data will be transmitted from the specified starting address and size. Refer to the address and size given in “Parameter Address Map” (p. 279).

*Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each packet will be sent at an interval of about 20 ms.

*Regarding the checksum, please refer to (p. 294)

*Not received when the Rx Sys.Excl parameter (SYSTEM/MIDI/SYSTEM MIDI) is OFF.

Status

Data byte

 

Status

F0H

41H, dev, 42H, 12H, aaH, bbH, ccH,

F7H

 

ddH, ... eeH, sum

 

 

Byte

Explanation

 

 

F0H

Exclusive status

 

 

41H

ID number (Roland)

 

 

dev

Device ID (dev: 10H)

 

 

42H

Model ID (GS)

 

 

12H

Command ID (DT1)

 

 

aaH

Address MSB:

upper byte of the starting address of the

 

 

transmitted data

 

bbH

Address:

middle byte of the starting address of the

 

 

transmitted data

 

ccH

Address LSB:

lower byte of the starting address of the

 

 

transmitted data

 

ddH

Data:

the actual data to be transmitted. Multiple bytes

 

 

of data are transmitted starting from the address.

:

:

 

 

eeH

Data

 

 

sum

Checksum

 

 

F7H

EOX (End Of Exclusive)

 

*The amount of data that can be transmitted at one time depends on the type of data, and data will be transmitted from the specified starting address and size. Refer to the address and size given in “Parameter Address Map” (p. 279).

*Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each packet will be sent at an interval of about 20 ms.

*Regarding the checksum, please refer to (p. 294)

*Not received when the Rx Sys.Excl parameter (SYSTEM/MIDI/SYSTEM MIDI) is OFF.

2. Data Transmission

Channel Voice Messages

Note off

Status

2nd byte

3rd byte

8nH

kkH

vvH

9nH

kkH

00H

n = MIDI channel number:

0H - FH (ch.1 - 16)

kk = note number:

 

00H - 7FH (0 - 127)

vv = note off velocity:

00H - 7FH (0 - 127)

Note on

Status

2nd byte

3rd byte

9nH

kkH

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

kk = note number:

 

00H - 7FH (0 - 127)

vv = note on velocity:

01H - 7FH (1 - 127)

Control Change

*By selecting a controller number that corresponds to the setting of parameters of controllers (C1–C4 Assign, and so on), the XV-88 can transmit any control change message.

Bank Select (Controller number 0, 32)

Status

2nd byte

3rd byte

BnH

00H

mmH

BnH

20H

llH

n = MIDI channel number:

0H - FH (ch.1 - 16)

mm, ll = Bank number:

00 00H - 7F 7FH (bank.1 - bank.16384)

*These messages are transmitted when Performance, Patch or Rhythm set is selected. But not transmitted when Program or Bank Sel parameter (SYSTEM/MIDI/TRANSMIT MIDI) is OFF.

*In Performance (Zone) mode, these messages are not transmitted when Bank Select MSB or P.C# parameter (ZONE/EXT CONTROL/EXT P.C) is NO-SEND.

*Although with the XV-88 you can select the Bank Select messages to be transmitted, be sure to refer to the Program Change Map on (p. 270) for the Bank Select messages transmitted when the XV-88 is select a Performance, Patch, or Rhythm Set.

*The Bank Select Numbers corresponding to SRX series should be referred to the SRX series owner's manual.

Modulation (Controller number 1)

Status

2nd byte

3rd byte

BnH

01H

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Modulation depth:

00H - 7FH (0 - 127)

Breath type (Controller number 2)

Status

2nd byte

3rd byte

BnH

02H

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Control value:

 

00H - 7FH (0 - 127)

Portamento Time (Controller number 5)

Status

2nd byte

3rd byte

BnH

05H

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Portamento Time:

00H - 7FH (0 - 127)

Data Entry (Controller number 6, 38)

Status

2nd byte

3rd byte

BnH

06H

mmH

BnH

26H

llH

n = MIDI channel number: 0H - FH (ch.1 - 16)

mm, ll = the value of the parameter specified by RPN/NRPN mm = MSB, ll = LSB

*When execute the GM Data Transfer, Data Entry messages will transmit.

276

Page 276
Image 276
Roland XV-88 owner manual 276, Data set 1DT1 12H