Bandwidthth Controll

TANDBERG VIDEO COMMUNICATION SERVER ADMINISTRATOR GUIDE

About Pipes

It is possible to control the amount of bandwidth used on calls between specific subzones and zones. The limits can be applied to the total concurrent bandwidth used at any one time, or to the bandwidth used by any individual call.

To apply these limits, you create a pipe and configure it with the required bandwidth limitations. You then assign the pipe to a link. Calls using the link will then have those bandwidth limitations applied to them.

Creating a new pipe

To create a pipe:

VCS Configuration > Bandwidth > Pipes. You will be taken to the Pipes page. Select New.

You will be taken to the Create Pipe page.

xCommand PipeAdd

Creating Pipes

Name

Enter the name you wish to give to this pipe.

You will refer to this name when creating links.

Total bandwidth mode

Determines whether there is a limit on the total concurrent bandwidth of this pipe.

Unlimited: no limitations are in place.

Limited: there is a limit in place; you must enter the limit in the field below.

None: there is no bandwidth available.

Total bandwidth (kbps)

Sets the limit on the total concurrent bandwidth of this pipe.

Per call bandwidth mode

Determines whether there is a limit on the bandwidth of individual calls via this pipe.

Unlimited: no limitations are in place.

Limited: there is a limit in place; you must enter the limit in the field below.

None: there is no bandwidth available.

Per call bandwidth (kbps)

Sets the limit on the bandwidth of individual calls via this pipe.

Create Pipe

Click here to create the pipe and return to the

Pipes page.

Introduction

Getting

System

System

H.323 & SIP

Registration

Zones and

Call

Firewall

Bandwidth

Maintenance

Appendices

Started

Overview

Configuration

Configuration

Control

Neighbors

Processing

Traversal

Control

 

 

 

D 14049.01

 

 

 

 

114

 

 

 

 

 

07.2007

 

 

 

 

 

 

 

 

 

Page 114
Image 114
TANDBERG D14049.01 manual About Pipes, Creating a new pipe, Creating Pipes, XCommand PipeAdd