H.323 Mode

Determines whether or not the VCS will provide H.323 gatekeeper functionality.

Registration UDP port

Specifies the port to be used for H.323 UDP registrations.

Call signaling TCP port

Specifies the port that listens for H.323 call signaling.

Call signaling port range start

Specifies the lower port in the range to be used by H.323 calls once they are established.

Call signaling port range end

Specifies the upper port in the range to be used by H.323 calls once they are established.

Save

Click here to save your changes.

Configuring H.323

Registration conflict mode

Determines how the system will behave if an endpoint attempts to register an alias currently registered from another IP address.

Reject: denies the registration.

Overwrite: deletes the original registration and replaces it with the new registration.

Time to live

Specifies the interval (in seconds) at which an H.323 endpoint must re-register with the VCS in order to confirm that it is still functioning.

Call time to live

Specifies the interval (in seconds) at which the VCS polls the endpoints in a call to verify that they are still in the call.

Auto discover

Determines whether or not the VCS responds to gatekeeper discovery requests from endpoints.

Introduction

Getting

System

System

H.323 & SIP

Registration

Zones and

Call

Firewall

Bandwidth

Maintenance

Appendices

Started

Overview

Configuration

Configuration

Control

Neighbors

Processing

Traversal

Control

 

 

 

D 14049.01

 

 

 

 

34

 

 

 

 

 

 

07.2007

 

 

 

 

 

 

 

 

 

 

Page 34
Image 34
TANDBERG D14049.01 manual Configuring H.323, XConfiguration H323