CommandText goes hereReference - xConfiguration

TANDBERG VIDEO COMMUNICATION SERVER ADMINISTRATOR GUIDE

Zones

Zone [1..200]

Match [1..5]

Mode: <AlwaysMatch/PatternMatch/Disabled>

cont...

cont...

 

Determines if and when a query will be sent to this zone.

 

 

 

Always: the zone will always be queried.

 

 

 

Pattern: the zone will only be queried if the alias queried for matches the corresponding pattern.

 

 

 

Disabled: the zone will never be queried.

 

 

 

Pattern

String: <S: 0, 60>

 

 

 

 

(applies only if the Match mode is Pattern Match)

 

 

 

 

Specifies the pattern against which the alias is compared.

Type: <Exact/Prefix/Suffix/Regex>

(applies only if the Match mode is Pattern Match) Determines the way in which the string must match the alias. Exact: the string must match the alias character for character. Prefix: the string must appear at the beginning of the alias. Suffix: the string must appear at the end of the alias.

Regex: the string will be treated as a regular expression.

Behavior: <Strip/Leave/Replace>

(applies only if the Match mode is Pattern Match)

Determines whether the matched part of the alias should be modified before an LRQ is sent to this zone.

Leave: the alias will be unmodified.

Strip: the matching prefix or suffix will be removed from the alias.

Replace: the matching part of the alias will be substituted with the text in the Replace string.

Replace: <S: 0, 60>

(applies only if the Pattern Behavior is Replace)

Specifies the string to be used as a substitution for the part of the alias that matched the pattern.

Priority: <1..65534>

Determines the order in which the zone will be sent a search request. Zones with priority 1 matches are searched first, followed by priority 2, and so on.

Name: <S: 1, 50>

Assigns a name to this zone.

Introduction

Getting

System

System

H.323 & SIP

Registration

Zones and

Call

Firewall

Bandwidth

Maintenance

Appendices

Started

Overview

Configuration

Configuration

Control

Neighbors

Processing

Traversal

Control

 

 

 

D 14049.01

 

 

 

 

145

 

 

 

 

 

07.2007

 

 

 

 

 

 

 

 

 

Page 145
Image 145
TANDBERG D14049.01 manual 145