0
50
100
150
200
250
0 20 40 60 80 100 120 140 160
SYSCLKOUT (MHz)
IDD IDDIO IDD3VFL IDDA Total 3.3−V current
Current (mA)
0
100
200
300
400
500
600
700
0 20 40 60 80 100 120 140 160
SYSCLKOUT (MHz)
TOTAL POWER
Power (mW)
SM320F2812-HT
www.ti.com
SGUS062A–JUNE 2009 –REVISED APRIL 2010
6.5 Current Consumption Graphs
A. Test conditions are as defined in Table 6-5 for operational currents under nominal process voltage and temperature
conditions.
B. IDD represents the total current drawn from the 1.8-V rail (VDD). It includes a trivial amount of current (<1 mA) drawn
by VDD1.
C. IDDArepresents the current drawn by VDDA1 and VDDA2 rails.
D. Total 3.3-V current is the sum of IDDIO, IDD3VFL, and IDDA. It includes a trivial amount of current (<1 mA) drawn by
VDDAIO.

Figure 6-2. Typical Current Consumption Over Frequency

Figure 6-3. Typical Power Consumption Over Frequency

Copyright © 2009–2010, Texas Instruments Incorporated Electrical Specifications 89
Submit Documentation Feedback
Product Folder Link(s): SM320F2812-HT