August, 2006 PUNCH UNIT (B702)
1-75
Installation
1.9.2 INSTALLATION
1. If the finisher is connected to the copier, disconnect the power connector [A]
and move the finisher away from the copier.
2. Remove the rear cover [B] ( x 2) and open the front door.
NOTE: At the bottom of the rear cover, make sure to disconnect the tabs that
attach the cover to the frame.
3. Remove the guide plate [C] ( x 2).
4. Remove the shipping retainer bracket [G] (screws [H]). Move the punching unit
[D] along its rails into the finisher. Make sure that the pin engages correctly at
the front and rear.
5. Connect and attach the punching unit [E] ( x 2, x 1).
The cables [F] are coiled and attached to the PCB.
Attach connectors to CN601 and CN602.
B702I102.WMF
B702I103.WMF
[A]
[B]
[C]
[D]
[E]
Rear
Front
[F]
[G]
[H]
[D]