August, 2006 PCU (PHOTOCONDUCTOR UNITS)
3-55
Reinstallation
1. Install the new cleaning unit [A] in the PCU.
2. Check the positions of the seals at the rear and front:
There must be no gap [B] between the edge of a seal and the edge of the
cleaning blade.
There must be no overlap [C] at the edge of the seal and the edge of the
cleaning blade.
Check that the cleaning blade does not catch on the edges of the seals as
shown in the drawing at "OK".
B132R208C.WMF
OK NG
NG
B132R208B.WMF
[A]
[B]