SERVICE CALL CONDITIONS April 2007 4-50
Fan error 4: fusing exhaust fan SC533 D
The lock signal remained HIGH for 5 sec.
while the fan that draws air out of the fusing
unit was operating.
Motor overload due to
obstacle interfering with
operation of the fan
Fan harness loose,
disconnected, defective
Fan defective
Fan error 5: duplex exhaust fan SC534 D
The lock signal remained HIGH for 5 sec.
while the fan that draws air out of the duplex
unit was operating.
Motor overload due to
obstacle interfering with
operation of the fan
Fan harness loose,
disconnected, defective
Fan defective
Temperature/Humidity control abnormal SC535 C
The output of the
temperature/humidity sensor
reaches the upper or lower limit,
even after the Peltier unit has
been ON for 3 hours.
Peltier Cooling Fan Motor is defective.
Heating roller thermistor 1 error 1: Poor connection SC541 A
The temperature measured by
the heating roller thermistor
does not reach 130°C after 10
tries and 65 sec. have elapsed.
Heating roller thermistor harness
connection loose, disconnected,
defective
Defective heating roller thermistor
Heating roller thermistor 1 error 2: No warmup
SC542 A
After the main switch is turned
ON or the cover is closed, the
heating roller temperature does
not reach the ready temperature
within 2 sec. after the heater
switches ON.
-or-
If the roller was below 45°C, the
heating roller did not reach the
ready temperature 2 sec. after
reaching 45°C.
Note: Thermistor 2 stops
monitoring the temperature once
Thermistor 1 detects ready
temperature.
Thermistor is bent, installed incorrectly
Defective heating roller thermistor
Heating roller fusing lamp broken
Do SP5810 to cancel the SC fusing code.