August, 2006 COPIER E-STUDIO4500C/5500C
1-35
Installation
Counter Display Setting
The default setting for the counter is "0" (development). Do the SP setting below to
set the counter for copy/print (paper count).
1. Enter the SP mode.
2. Do SP5045 001 (Counter Display Setting).
3. Select the counter to use:
0 Development counter (Default)
1 Page counter
Important!
THIS SETTING CAN BE DONE ONLY ONCE. AFTER IT IS SET TO "1", THE COUNTER
SETTING CANNOT BE CHANGED. IF THE WRONG SETTING IS SELECTED BY MISTAKE,
CONTACT YOUR TECHNICAL SUPERVISOR.
Print an SMC Report
1. Enter the SP mode.
2. Do SP5990 001 to print a full SMC report. Keep it in a safe location, with the
factory setting sheet.