SERVICE PROGRAM TABLES April, 2007 5-102
4646
Scan Auto Error Error Flag for Automatic Adjustment: Scanning DFU
This SP sets the error flag to display as the SBU is updated automatically when the
machine is switched ON.
001
Gain
002
K Level [0x00~0xFFFF]
b7 GAIN_ERR_BO
b6 GAIN_ERR_BE
b5 GAIN_ERR_BK_GO
b4 GAIN_ERR_BK_GE
b3 GAIN_ERR_GO
b2 GAIN_ERR_GE
b1 GAIN_ERR_RO
b0 GAIN_ERR_RE
4647
HW Error Flag Hardware Error Flag Adjustment: Scanning DFU
This SP sets the error flag to confirm machine ON processing when the machine is
switched ON.
[0x00~0x3F]
4680
Fact Gain Adj:R Factory Gain Adjustment at Factory: Red DFU
When switched ON, this SP displays the setting do ne at the factory for RED O
(ODD) and E (EVEN) gain in the ASCI on the SBU after white level adjustment every
time the machine is switched ON.
001
RE
002
RO [0~1023/1]
4681
Fact Gain Adj:G Factory Gain Adjustment at Factory: Green DFU
When switched ON, this SP displays the setting done at the factory for GREEN and
black-and-white O (ODD) and E (EVEN) gain in the ASCI on the SBU after white
level adjustment every time the machine is switched ON.
001
Color:GE
002
Color:GO
005
B/W:GE
006
B/W:GO
[0~1023/1]
4682
Fact Gain Adj:B Factory Gain Adjustment at Factory: Blue DFU
When switched ON, this SP displays the setting do ne at the factory for BLUE O
(ODD) and E (EVEN) gain in the ASCI on the SBU after white level adjustment every
time the machine is switched ON.
001
BE
002
BO [0~1023/1]
4690
White Lvl Peak:R White Level Peak: Red Scan Data DFU
When switched ON, these SP codes display E (EVEN) or O (ODD) for the white
level peak RED data after white level detection (AGC) after the machine is switched
ON.
001
RE
002
RO [0~255/1]