SERVICE CALL CONDITIONS April 2007 4-44
SC440 D
Image transfer power pack error 1: K
SC441 D
Image transfer power pack error 2: M
SC442 D
Image transfer power pack error 3: C
SC443 D
Image transfer power pack error 4: Y
An interrupt checks the status of
the power pack every 2 ms. This
SCis issued if the BICU detects a
short in the power pack for K, M,
C, or Y 250 times within 500 ms.
Transfer belt damaged, insulation
damaged
Insulation on high voltage cable
damaged
Another hot point inside the machine has
damaged insulation
Insulation around high-voltage power
supply damaged
IOB damaged
Image transfer motor error SC445 D
The control board of the image
transfer motor generated signals
that indicate there is problem
with the image transfer motor.
Image transfer motor defective
ITB control board defective
ITB overloaded
Encoder strip on the front edge of the
belt damaged.
ITB lift motor error SC446 D
The state of the ITB lift sensor
does not change its state
(switching from OFF to ON or
vice versa), even after the ITB
lift motor starts rotating.
ITB lift sensor dirty, disconnected,
defective
ITB lift motor disconnected, defective
Transfer power pack output error SC450 D
An interrupt checks the status of
the power pack every 2 ms. This
SC is issued if the BICU detects
a short in the power pack 250
times at 2nd transfer output
within 500 ms.
Damaged insulation on the high-voltage
supply cable
Damaged insulation around the high-
voltage power supply.
PTR motor error SC455 D
The lock signal from the paper
transfer motor is not detected
within 1 sec. after the motor
switched ON.
Motor disconnected
PTR shaft locked, needs cleaning,
blocked by obstruction
Drive shaft of the ITB locked and
overloaded, needs cleaning, or blocked
by obstruction
DRB (motor drive board) disconnected,
defective